8
05.01
8.7 Circuit examples =1 to =9 with SIMODRIVE 611
8-273
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Ext. push-
D3
On/off/EMERGENCY STOP
Drives on/of
f/stopping in an emergency; start/stop/safe standstill
3TK2806–0BB4
machine control! insert!
Circuit example =4
01
1
1L–
0 V DC
N/L–
23
X2
X6
X4
Insert jumper or safety–relevant
monitoring circuits
of the user–side
R5
–K24
3.5
–K33
.6
R1
62
62
61
H1
.5
–K23
1.0
–A10
–K21
61
62
1.2
1.1
213
61
L1/L+
V1
111
K1
D1
K1
K1
K3
R3
H3
K2
K3
EMERGENCY STOP
X1
X3
–S24
control
off/on
Drives
.6
On
–S23
max. 2
A
–F21
–S21
3.8 37
3.8
38
=1/2.4
–S22
NC–READY
Drives
Off
2
–K25
=1–A25
14
1
13
.7
=7/1.4
=7/1.3
1)
75
76
81
=8/1.2
92
=9/1.7 =9/1.7
91
82
2)
=8/1.2
14 3.2
24 =5/1.2
34 =1/1.7
13
23
43
61
53
71
83
33
–K23
4
14
24
34
5
84
24 =5/1.1
62 .1
34 =1/1.7
54
72
44
81
6
82
61
53
71
23
43
33
62 .1
54
72
44
14 3.2
A2
A1
44
54
66
–K24
A2
13
A1
4
25.04.2001
A3431–820937
KIC
=
+
Sh.
22 .7
21
43
33
44
34
7
14 .3
–K25
13
A2
A1
A25
22 3.1
44
34
8
21
43
33
9
14 1.9
–K27
13
A2
A1
3.9
24
1
1L–
Drives
K2
K3
D2
R2
K1
H2
K2
K1
K2
K3
Stopping
emergency!
X5
in an
13
23
33
43
53
65
3) Open jumper
, term. 91 –92
for armature short–circuit braking, circuit = 9
1) Open jumper
, term. 75 –76
for external speed monitoring MSD, circuit = 7
2) Open jumper
, term. 81 –82
for limit switch limit position monitoring, circuit = 8
3)
Off
Drives
PLC
Drives
Off
PLC
–S22
I21
–K21
65
66
I22
.3
–S23
.1
Ready for operation
PLC
NE module
Holding brake
–K36
23
O27
PLC
Option
feedback
On
PLC
link
Contactor
PLC
I23
E25
–K25
.7
21
22
–S28
Start
NC program
Stop
PLC
PLC
I28
I29
–S29
Machine
control panel
1
1L+
12L+
24 V DC
24 V DC
1
1L+
12L+
1
2
Sh.
.5
.1
.6
button
Fig. 8-16
=4 On/off//stopping in an emergency; start/stop/safe standstill; Sheet 1/2
8 Important Circuit Information
05.08