12
05.01
12-432
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
PRO/E–CAD
* Pro/E *
2
Belonging to this:
1
345
E
D
C
B
A
123
CAD–Drawing
Manuel modification
prohibited
456
78
E
D
C
B
A
Cond.
Message
Date
Name
Siemens A
G
Dept.
Standard
T
ested by
Handled by
Date
Scale:
Type/MLFB:
Page:
P.
Replacement for / replaced by:
F
A & D
Equipment Plant Erlangen
DIN 6
L
T–400A
300
150
–
2
0
L
T–300A
300
95
–
1
8
L
T–200A
300
95
–
1
8
E/R–120/156kW
300
150
25
E/R–80/104kW
300
95
22
E/R–55/71kW
300
95
21.5
[ mm ]
[kg]
Module
Modul
Module width
Modulbreite
Module weight
Modulgewicht
Allg.T
oleranz
Surface:
1:4
kg/piece:
ISO
2768–mk
. .
T
olerierung
. .
.
ISO
8015
. .
.
03.02.95
Knauer
Maßblatt Module 300 mm
Masatz
externe Entwärmung
ae
506685
12.1
1.98
Sch
ad
501744
13.10.95
Fe
M
C
E
4
5
SIMODRIVE 6SN1
1
ac
500997
20.06.98
Kn
ab
500375
07.03.95
Kn
2 GE.
462108.9001.00
–
a
e
1
aa
50001
1
07.02.95
Kn
3
Bei Modulmontage einzuhaltende
Anzugsdrehmoment
Required tightening torque
for module assembly
ad
ad
ad
100
100
213
186
56
90
18
92
120
24.8
±
0.15
250
±
0.3
100
±
0.3
150
±
0.3
466
±
0.3
8
±
0.15
480
20
12.2
233
128
79.5
8
±
0.1
506
±
0.1
520
300
Lüftungsfreiraum
Free space
for cooling air
Lüftungsfreiraum
Free space for cooling air
IP20
12)
IP54
Montagerahmen 300mm
Mounting frame 300mm
5)
7),1
1)
3)
4)
9)
2)
10)
Montageebene
Mounting plane
1)
6)
14)
8)
13)
Umgebungstemperatur:
0
°
C bis 40
°
C
Ambient temperature: 0
°
C until 40
°
C
Screws M3: 0.8 Nm
(7
in
lb)
Screws M4: 1.8 Nm
(16
in
lb)
Screws M5: 3 Nm
(26
in
lb)
Screws M6: 6 Nm
(52
in
lb)
Screws M8: 13 Nm
(1
12
in
lb)
Screws M10: 20 Nm
(173
in
lb)
Schrauben M3: 0,8 Nm
SchraubenM4: 1,8 Nm
Schrauben M5: 3 Nm
Schrauben M6: 6 Nm
Schrauben M8: 13 Nm
Schrauben M10: 20 Nm
1)
Regelung gesteckt und verschraubt
Achtung!
V
erschraubung gewährleistet PE- und Schirmverbindung
für Geber- und Sollwert (Entfällt bei Modulen mit Impulsschnittstelle)
2)
Anschlussklemmenbereich
3)
Anschlussklemmenbereich U, V
,
W:
Anzugsdrehmomente siehe Kapitel 5.6.2 und 6.2.3
4)
PE-Anschluss
5)
Combicon-Klemmen (Anlieferzustand gesteckt)
(Entfällt bei Modulen mit Impulsschnittstelle)
6)
Zusätzliche Anschlussmöglichkeit für Schirmauflage M5x10
(Geber
, Sollwert)
7)
Abdeckung eingerastet
8)
Bohrung für Befestigungsgewinde M5 bzw
. 10-24 UNC-2A 10-32 UNF-2A
9)
Gehäuse: Blech DIN EN 10143 FE P0 3G Z140 M8-0-1.5
10)
Frontplatte: Kunststoff
1
1
)
Abdeckung: Kunststoff
12)
Bei Modulen mit Impulsschnittstelle: IP00
13)
Anschlussbereich L1, L2, X131: Anzugsdrehmoment 1,5 ... 1,8 Nm
Max. Anschlussquerschnitt unter V
erwendung von Stiftkabelschuhen möglich
14)
Lüftergewicht: 4 kg
1)
Control board inserted screwed in
Attention! Screw in to ensure the galvanic contact for PE-and encoder cable shield
(Not included in modules with pulse-interface)
2)
T
erminal block area
3)
T
erminal
U,
V
,
W:
T
ightening torques see Chapter 5.6.2 and 6.2.3
4)
PE-connection
5)
Combicon-terminal (plugged for delivery)
(Not included in modules with pulse-interface)
6)
Additional connection possible for cable screening M5x10
(encoder
, reference value)
7)
Cover engaged
8)
Cut out for fastening screw M5 or 10-24 UNC-2A 10-32 UNF-2A
9)
Material: Metal sheet DIN EN 10143 FE P0 3G Z140 M8-0-1.5
10)
Front cover: plastic
1
1
)
Cover: plastic
12)
Modules with pulse-interface: IP00
13)
T
erminal L1, L2, X131: tightening torque 1,5 ... 1,8 Nm
Max. cross-section only applicable with pin terminal
14)
Fan weight: 4 kg
Max. conductor cross-section [mm
2
]
Max. Anschlussquerschnitt [mm
2
]
16
16
16
Confié
à
titre de secret d’entreprise. T
o
us droits réservés.
Confiado como segreto de empresa. Nos reservamos todos los derechos.
Comunicado como segredo empresarial. Resrevados todos os direitos.
Transmittal, reproduction, dissemination and/or editing of this document
as well as utilization of its contents and communication thereof to
others without express authorization are prohibited. Offenders will be
held liable for payment of damages. All rights created by patent grant
or registration of a utility model or design patent are reserved.
Weitergabe sowie Vervielfältigung, Verbreitung und/oder Bearbeitung
dieses Dokumentes, Verwertung und Mitteilung seines Inhaltes sind
verboten, soweit nicht ausdrücklich gestattet. Zuwiderhandlungen ver-
pflichten zu Schadenersatz. Alle Rechte für den Fall der Patentertei-
lung, Gebrauchsmuster- oder Geschmacksmustereintragung vorbehalten.
U,
V
,
W
3)
L1,
L2, X131
13)
Fig. 12-40 External cooling, 300 mm PM module 6SN1124–1AA0x–0xA1 and I/R module 6SN1146–1BB00–0xA1;
Sheet 1
12 Dimension Drawings
02.07
02.12