2.3 Motor selection
2-48
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
2.3
Motor selection
The Motor Configuration Manuals are used to select the drive motors.
Reader’s note
You can find information on the following motors under the following link:
S
Ordering documentation/overview of documents
–
→
Printed documentation
→
Docu_SIMOTICS
–
→
DoConCD/User Manual Collection
S
Links to download documents
→
Download documentation
→
SIMOTICS S servomotors
→
SIMOTICS M main motors
S
Using documentation online (finding and searching in manuals/information)
http://www.siemens.com/motioncontrol/docu
The selection of the motor and the (brief) overload capability determines he size
(rating) of the power module (refer to Chapter 4).
A voltage protection module (VPM) is required for motors 1FE1 and 2SP1 with
an EMF > 800 V and maximum < 2 kV (> 565 V
eff
up to a maximum 1400 V
eff
).
When a fault condition develops, the VPM limits the DC link voltage at the drive
converter.
Technical data and ordering data, refer to 8.16.
Reader’s note
Reference:
/PJFE/ Configuration Manual, 1FE1 Synchronous Built–in
Motors
/BU/
Catalog NC 60
/PMS/ Configuration Manual ECO Motor Spindles for
2SP1 Main Spindle Drives
Selection
VP module (VPM)