2 System Configuration
2
05.01
2.7 Infeed modules
2-58
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Hose cooling for a 1 tier configuration
Package 1 for a single module
Version for the Order no.
6SN1145–1BB00–0DA
V
6SN1145–1BB00–0EA
V
6SN1145–1BB00–0FA
V
6SN1123–1AA01–0FA
V
6SN1123–1AA00–0JA
V
6SN1123–1AA00–0KA
V
(Order No. 6SN11 62–0BA03–0AA1)
Pipe cooling for a 2–tier configuration
Packet 2 for a 2–tier design
Version for the Order no.
6SN1145–1BB00–0DA
V
6SN1123–1AA02–0FA
V
(Order No. 6SN11 62–0BA03–0CA1)
Minimum,
300 mm
I/R
PM
Fig. 2-7
System configuration with hose cooling (only for 300 mm wide modules)
The 2–tier design with pipe cooling is only permissible for the combination of
modules, order no. 6SN1145–1BB00–0DA
j
at the top and
6SN1123–1AA02–0FA
j
at the bottom.
Note
DC link connection, refer to Chapter 9.1.3.
For connection details for the DC link adapter set, refer to the dimension
drawing in Chapter 12.