4
05.01
4.1 Closed–loop control with digital setpoint interface
4-86
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
1–axis version
High Performance
2–axis version
High Performance/High Standard
0.5 Nm
0.5 Nm
M3/0.8 Nm
M3/0.8 Nm
DAC 1
DAC 2
DAC 3
Ground
DAC assignment
DAC 1
DAC 2
DAC 3
Ground
DAC assignment
M3/0.8 Nm
Fig. 4-2
Digital control High Performance and High Standard without direct measuring system
Notice
When using non–PELV circuits at terminals AS1, AS2, connectors must be
coded to prevent the connectors being incorrectly inserted (refer to
EN60204–1, Section 6.4).
For the order number for coded connectors, refer to Catalog NC 60.
!
Warning
At terminals 19, P24 and M24, only PELV circuits may be connected. If this is
not carefully observed, then this can result in personal injury in the form of
electric shock.
4 Control Units
11.05