4.1 Closed–loop control with digital setpoint interface
4-89
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Table 4-5
Encoder signal input of direct measuring system X421. X422
Pin
X421 (axis 1)
X422 (axis 2)
Function
1
PENC
Encoder power supply
2
MENC
Encoder power supply ground
3
AP
Incremental signal for track A
4
AN
Inverse incremental signal for track A
5
ENDATDAT
Data signal EnDat interface
6
BP
Incremental signal for track B
7
BN
Inverse incremental signal for track B
8
XENDATDAT
Inverse EnDat interface data signal
9
PSENSE
Remote sense encoder power supply (P)
10
RP
Reference mark signal/zero pulse
11
MSENSE
Remote sense encoder power supply (N)
12
RN
Inverse reference mark signal/zero pulse
13
M
Inner shield ground
14
ENDATCLK
EnDat interface clock signal
15
XENDATCLK
Inverse clock signal, EnDat interface
Note:
The inputs on the control must not be assigned any signals other than the intended sig-
nals. Otherwise, sporadic or permanent malfunction or damage can occur.
It is especially important for spindle applications, that possibly available signals from
additional temperature sensors (PTCs, NTCs or similar) must NOT be connected to the
CP–, CN–, DP–, DN inputs that are not used when using induction motors!
When ”parking axis” is selected, the encoder can be withdrawn and inserted also under
voltage.
Encoder
connection
X421/X422
4 Control Units
02.12