4
05.01
4.2 ”SIMODRIVE 611 universal HRS” control board
4-95
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
An additional 8 digital inputs and outputs can be realized using this optional
module.
The functionality of these inputs/outputs can be freely parameterized.
Note
S
The input/output terminals of the optional TERMINAL module are
–
Before SW 4.1: permanently assigned to drive A or axis A
–
As of SW 4.1: can be freely assigned axes
S
The optional TERMINAL module can be used as follows, dependent on the
software release:
–
The following applies before SW 2.4:
The module can only be used in the ”positioning” mode.
–
The following applies as of SW 2.4:
The module can be used independently of the operating mode.
Order number: 6SN1114–0NA00–0AA0
I4
I5
I6
I7
I8
I9
I10
I11
O4
O5
O6
O7
O8
O9
O10
O11
X422
8 inputs
X432
8 outputs
For screws:
Tighten (due to the shield contact)
max. torque = 0.8 Nm
Fig. 4-6
Optional TERMINAL module
Optional terminal
module
4 Control Units
02.03