Model Designations and Specifications
UMSITRPDS3-1
November
2010
9-26
Additional Model 7MF4633 (7MF4812) Selections and Data*
Order
Code
O-rings for process flanges on low pressure side (instead of FPM (Viton))
- PTFE (Teflon)
A20
- FEB (with silicone core, approved for food)
A21
- FFPM (Kalrez, compound 4079)
A22
- NBR (Buna N)
A23
Plug: Han 7D (metal, gray)
A30
Plug: Han 8U (instead of Han 7D)
A31
Sealing screws: 1/4-18 NPT with valve in material of process flanges
A40
Cable sockets for M12 connectors (metal)
A50
Inscribing of rating plate (instead of German):
- English
B11
- French
B12
- Spanish
B13
- Italian
B14
- English, pressure units in inH
2
O or psi
B21
Manufacturer’s test/calibration certificate M to DIN 55350, Part 18 and to ISO 8402
C11
Acceptance test certificate to EN 10204-3.1
C12
Factory certificate to EN 10204-2.2
C14
“Functional Safety (SIL)” certificate
C20
Setting of upper limit of output signal to 22.0 mA
D05
Type of protection IP 68
D12
Supplied with oval flange
D37
Use on Zone 1D/2D
E01
Use on Zone 0
E02
Overfilling safety device for flammable and non-flammable liquids, PN 32 (MVWP 464 psi) maximum
E08
Explosion proof, intrinsic safety to INMETRO (Brazil)
E25
Explosion proof, intrinsic safety to NEPSI (China)
E55
Explosion protection, explosion proof to NEPSI (China)
E56
Explosion proof, Zone 2 to NEPSI (China)
E57
Interchanging of process connection side
H01
Measuring to be set, specify in plain text, Y01: ... to ... mbar, bar, kPa, Mpa... (5 characters maximum)
Y01
Specify tag number/descriptor, 16 characters maximum, in plain text
Y15
Specify tag message, 27 characters maximum, specify in plain text:
Y16
Entry of HART address (Tag)
Y17
Setting of pressure indicator in pressure units, specify in plain text: mbar, bar, kPa, MPa, ...
Y21
Setting of pressure indicator in non-pressure units, specify in plain text: l/min, m
3
/h, m, USgpm...
Y22+Y01
Only Y01, Y21, Y22, Y25 and D05 can be factory preset.
* Add “-Z” to model number and specify Order Code(s).
Summary of Contents for 7MF4033 series
Page 48: ...Model 275 Universal Hart Communicator UMSITRPDS3 1 November 2010 2 26 ...
Page 86: ...Installation UMSITRPDS3 1 November 2010 4 34 ...
Page 152: ...Calibration and Maintenance UMSITRPSD3 1 November 2010 7 20 ...
Page 158: ...Circuit Description UMSITRPDS3 1 November 2010 8 6 ...
Page 197: ......
Page 198: ......
Page 200: ...Model Designations and Specifications UMSITRPDS3 1 November 2010 9 42 ...
Page 204: ...Glossary UMSITRPDS3 1 November 2010 10 4 ...
Page 208: ...Appendix A Online Configuration Map UMSITRPDS3 1 11 4 November 2010 ...
Page 216: ...Appendix C Elevation and Suppression Correction UMSITRPDS3 1 13 4 November 2010 ...