Model Designations and Specifications
UMSITRPDS3-1
November
2010
9-30
9.6 SERVICE PARTS, ALL MODELS
Tables 9-12 through 9-18 list the measuring cells and circuit boards available for servicing a transmitter
described in this publication.
TABLE 9-12 Measuring Cells for Pressure, Service Parts
DS III and DS III PA series, 7MF4990-
0
- 0DC0
Measuring cell filling
Measuring cell cleaning
Silicon oil
Normal
1
Inert liquid
Grease-free
3
Measuring span
0.01 to 1 bar g
(0.15 to 14.5 psi g)
B
0.04 to 4 bar g
(0.58 to 58 psi g)
C
0.16 to 16 bar g
(2.32 to 232 psi g)
D
0.63 to 63 bar g
(9.14 to 914 psi g)
E
1.6 to 160 bar g
(23.2 to 2320 psi g)
F
4.0 to 400 bar g
(58.0 to 5802 psi g)
G
Wetted parts materials
Seal diaphragm Process
connection
Stainless steel
Stainless steel
A
Hastelloy
Stainless steel
B
Hastelloy
Hastelloy
C
Process connection
Connection shank G1/2A to EN 837-1
0
Female thread 1/2-14 NPT
1
Oval flange of stainless steel, span: 160 bar (2320 psi) maximum
- Mounting thread 7/16-20 UNF to EN 61518
2
- Mounting thread M10 to DIN 19213
3
Additional selection: Add ”–Z” to model number and specify Order Code
Order Code
Acceptance test certificate to EN 10204-3.1
C12
Summary of Contents for 7MF4033 series
Page 48: ...Model 275 Universal Hart Communicator UMSITRPDS3 1 November 2010 2 26 ...
Page 86: ...Installation UMSITRPDS3 1 November 2010 4 34 ...
Page 152: ...Calibration and Maintenance UMSITRPSD3 1 November 2010 7 20 ...
Page 158: ...Circuit Description UMSITRPDS3 1 November 2010 8 6 ...
Page 197: ......
Page 198: ......
Page 200: ...Model Designations and Specifications UMSITRPDS3 1 November 2010 9 42 ...
Page 204: ...Glossary UMSITRPDS3 1 November 2010 10 4 ...
Page 208: ...Appendix A Online Configuration Map UMSITRPDS3 1 11 4 November 2010 ...
Page 216: ...Appendix C Elevation and Suppression Correction UMSITRPDS3 1 13 4 November 2010 ...