7SG11 Argus 2 Diagrams and Parameters
©2010 Siemens Protection Devices Limited
P20009 Page 5 of 37
Section 1: Variants
This document applies to the Argus relays listed in the following MLFB Structure & table.
The MLFB Structure references the complete number for each relay:
•
7SG11nn-nxxnn-nxA0
where n is a digit and x is a letter.
The table uses two references for most relays, each of which is valid:
•
an ‘Order code’ of the form AG
n
-
nnn
, and
•
a ‘Type’ of the form DCD
nnn
X
where
n
is a digit and X is a letter.
Order code
/ Type
30/48 aux.
110/220 aux.
Protection
Application
Diagram
I/O
30V status
48V status
48V status
110V status 220V status
Directional earth-fault
Fig. 4-1
1 SI
7 OR
DCD211A
AG2-101
DCD213A
AG2-102
DCD214A
DCD215A
DCD216A
Directional sensitive earth-fault Fig.
4-2
1 SI
7 OR
DCD221A
AG2-103
DCD223A
AG2-104
DCD224A
DCD225A
DCD226A
5 SI
11 OR
DCD611B
AG2-311
DCD613B
AG2-312
DCD614B
DCD615B
DCD616B
3 directional phase-fault
Fig. 4-3
9 SI
7 OR
DCD611C
AG2-321
DCD613C
AG2-322
DCD614C
DCD615C
DCD616C
5 SI
11 OR
DCD621B
AG2-313
DCD623B
AG2-314
DCD624B
DCD625B
DCD626B
2 directional phase-fault and SEF Fig. 4-4
9 SI
7 OR
DCD621C
AG2-323
DCD623C
AG2-324
DCD624C
DCD625C
DCD626C
5 SI
11 OR
DCD631B
AG2-315
DCD633B
AG2-316
DCD634B
DCD635B
DCD636B
2 directional phase-fault and
directional earth-fault
Fig. 4-5
9 SI
7 OR
DCD631C
AG2-325
DCD633C
AG2-326
DCD634C
DCD635C
DCD636C
5 SI
11 OR
DCD641B
AG2-317
DCD643B
AG2-318
DCD644B
DCD645B
DCD646B
2 phase-fault and dir’n. earth-fault Fig. 4-6
9 SI
7 OR
DCD641C
AG2-327
DCD643C
AG2-328
DCD644C
DCD645C
DCD646C
5 SI
11 OR
DCD811B
AG2-411
DCD813B
AG2-412
DCD814B
DCD815B
DCD816B
3 directional phase-fault and
directional earth-fault
Fig. 4-7
9 SI
7 OR
DCD811C
AG2-421
DCD813C
AG2-422
DCD814C
DCD815C
DCD816C
5 SI
11 OR
DCD821B
AG2-413
DCD823B
AG2-414
DCD824B
DCD825B
DCD826B
3 directional phase-fault and SEF Fig. 4-8
9 SI
7 OR
DCD821C
AG2-423
DCD823C
AG2-424
DCD824C
DCD825C
DCD826C
5 SI
11 OR
DCD831B
AG2-415
DCD833B
AG2-416
DCD834B
DCD835B
DCD836B
3 phase-fault and
directional earth-fault
Fig. 4-9
9 SI
7 OR
DCD831C
AG2-425
DCD833C
AG2-426
DCD834C
DCD835C
DCD836C
5 SI
11 OR
DCD911B
AG2-511
DCD913B
AG2-512
DCD914B
DCD915B
DCD916B
3 directional phase-fault and
directional earth-fault
under/overvoltage
Voltage and power measurements
Fig. 4-10
Fig. 4-11
9 SI
7 OR
DCD911C
AG2-521
DCD913C
AG2-522
DCD914C
DCD915C
DCD916C
5 SI
11 OR
DCD921B
AG2-513
DCD923B
AG2-514
DCD924B
DCD925B
DCD926B
3 dir’n. phase-fault and SEF, or
2 dir’n. P/F, dir’n. E/F and SEF
and under/overvoltage
Voltage and power measurements
Fig. 4-12 to
Fig. 4-14
9 SI
7 OR
DCD921C
AG2-523
DCD923C
AG2-524
DCD924C
DCD925C
DCD926C