Interfaces
D-Sub 9 for Time Synchronization (X1)
Connection
9-pin D-sub socket
Cable length
Max. 10 m for electrical outputs with specified
Siemens accessories (see
)
Electrical outputs
2 outputs, 24 V on pin 1/3 and pin 4/8
Rated output voltage
DC 24 V (-20 % and +10 %)
Rated output current
50 mA per output (with 2‑channel wiring on the
output side) or 55 mA (with 1‑channel wiring on the
output side)
Maximum output current
Protocols
IRIG B
Pulses per second (PPS)
DCF77
Minute pulse
Minimum pulse length
2 ms
Optical Interface (R1, R2)
Optical receivers
2 receivers, factory setting: light idle state: OFF
Fiber-optic connection
ST bayonet closure
Data indication RCV1
LED, yellow, channel 1 receive
Data indication RCV2
LED, yellow, channel 2 receive
Wavelength
820 nm
Sensitivity
-30 dBm
Optical budget
10 dB (+ 3-dB system reserve)