Operating Instructions 

7XV5810 0xA00 

 

 

1.4 

Statement of Conformity 

  Low-voltage Directive 2014/35/EU 

EMC Council Directive 2014/30/EU 
This conformity has been established by means of tests conducted by 
Siemens AG according to the Council Directive in agreement with the 
generic standard EN 60255-26 for the EMC directives, and with the 
standard EN 61010-1 for the low-voltage directive. 

1.5 Further 

Standards 

This product is UL-certified, based on the technical data acc. to Standard UL 61010-
1, third edition; UL File No.: E228586 

Measuring

 

Equipment

E228586

1.6 Used 

Symbols 

Nr. Symbol  Description 

 

Direct current: IEC 60417-5031 

 

Alternating current: IEC 60417-5032 

 

Direct and alternating current: IEC 60417-5033 

 

Earth (ground) terminal: IEC 60417-5017 

 

Protective conductor terminal: IEC 60417-5019 

 

Caution, risk of electric shock 

 

Caution, risk of danger: ISO 7000-0434 

 

Protective Insulation IEC 60417-5172 

Safety Class II devices 

 

Guideline 2002/96/EC for electrical and electronic old devices 

Summary of Contents for 7XV5810 0BA00

Page 1: ...Wide range power supplies 7XV5810 0BA00 24 V 7XV5810 0CA00 5 V Operating Instructions ...

Page 2: ...8 1 13 Switching off the device 8 1 14 Installation 8 1 15 Connection 9 1 16 Commissioning 9 1 17 Maintenance 10 2 TECHNICAL DATA 11 2 1 Power supply 7XV5810 0BA00 24 V 11 2 2 Power supply 7XV5810 0CA00 5 V 12 2 3 Combined specifications 13 2 4 Dimension Drawings 18 2 5 Connection terminals 7XV5810 0BA00 24 V 19 2 6 Connection terminals 7XV5810 0CA00 5 V 19 2 7 Ordering Data 20 Figures Figure 1 Di...

Page 3: ...nd to put into action for each individual case the safety instructions and warnings given in this document in a general manner This manual is an integral part of the scope of delivery However it cannot take into account every detail on all types of the described product and also every possible case regarding installation operation or maintenance If further information is desired or in case special...

Page 4: ...egard of the corresponding precautionary measures may cause death severe bodily injury or considerable property damage Attention Disregard of the corresponding precautionary measures may lead to slight bodily injury or minor property damage Note Shall draw your attention to special information on the product product handling or the corresponding section of the documentation Qualified personnel Com...

Page 5: ...e device must be operated only within the scope of its intended use according to these operating instructions and in connection with third party equipment or compounds recommended or accepted by Siemens Faultless and safe operation of the product require proper transport storage mounting and installation as well as careful operation and maintenance 1 3 Customer Support For any questions concerning...

Page 6: ...tive 1 5 Further Standards This product is UL certified based on the technical data acc to Standard UL 61010 1 third edition UL File No E228586 Measuring Equipment E228586 1 6 Used Symbols Nr Symbol Description 1 Direct current IEC 60417 5031 2 Alternating current IEC 60417 5032 3 Direct and alternating current IEC 60417 5033 4 Earth ground terminal IEC 60417 5017 5 Protective conductor terminal I...

Page 7: ...eviewed at regular intervals Necessary corrections will be included in the next edition You are invited to send us your suggestions for improvement 1 8 Copyright Copyright Siemens AG 2018 All rights reserved Transmission or reproduction of this document as well as the use and forwarding of its contents is not permitted without express written authority Offenders will be liable for damages All righ...

Page 8: ...it is short circuit proof for an unlimited amount of time In case of a short circuit longer than 5 seconds the device must be switched off for more than 30 seconds or be operated in open line operation to be ready for operation again 1 13 Switching off the device After the switching off of the device and the decrease of the GOK relay the device must stay off during 3 5 seconds before it can be swi...

Page 9: ...e labelled accordingly A safety cutout can possibly act in both functions Recommended stripping length 5 mm The output voltage of the power supply conducted to the consumer must be done with cables that are isolated twice or are separated from the network cables 1 16 Commissioning Check whether the operation data comply with the values on the rating plate Do not make any changes at the device Clip...

Page 10: ...10 von 20 Operating Instructions 7XV5810 0xA00 1 17 Maintenance The wide range power supplies require no maintenance For cleaning please use a dry and free of fuzz rag Note Do not use any liquid agents or substances for cleaning ...

Page 11: ...al load Power supply Vaux Alternative current AC 60 V to 230 V 20 45 Hz to 65 Hz Higher harmonics allowed 2 kHz Maximum inrush current at 115 V 15 A Maximum inrush current at 230 V 22 A after 250 µs 5 A Power input 25 VA Output Connection 2 pole terminal Rated output current Max 250 mA Behavior in case of short circuit mains buffering permanent Power supply failure At least 50 ms at nominal load S...

Page 12: ... 5 A Degree of efficiency 50 at nominal load Power supply Vaux Alternative current AC 60 V to 230 V 20 45 Hz to 65 Hz Higher harmonics allowed 2 kHz Maximum inrush current at 115 V 15 A Maximum inrush current at 230 V 22 A after 250 µs 5 A Power input 12 VA Output Connection 2 pole terminal Rated output current 600 mA Behavior in case of short circuit mains buffering permanent Power supply failure...

Page 13: ...idity on 30 days per year Condensation during operation Not allowed Condensation during transport and storage Allowed Other environmental indications Maximum height over sea level 2000 m Degree of pollution 2 Class of protection according to IEC 60529 IP 20 Overvoltage category III Alarm relay Relay MSR Relay 1 NC open contact Potential free 2 pole connector Maximum switching voltage nominal value...

Page 14: ...tion Auxiliary power to relay Auxiliary power to RS232 interface Fault relay to RS232 interface each DC 5 kV 1 s with bypass capacitors AC 3 51 kV 50 Hz 1 s without bypass capacitors each 6 4 kV peak 1 2 µs 50 µs 0 5 J 3 pos und 3 neg surges in Intervals of 5 s All circuits Class III not on open contacts EMC Tests on interference emission Standard EN 50081 1 Conducted interference only power suppl...

Page 15: ...EC 60255 26 Class IV EN 61000 4 4 Class IV Fast transient disturbances Burst IEC 61000 4 4 Class III IEC 60255 26 Class III EN 61000 4 4 Class III 100 kHz and 30 surges per minute Test duration 1 minute 2 5 kV longitudinal voltage 1 kV transverse voltage 6 kV contact discharge 8 kV air discharge both polarity 150 pF Ri 330 Ohm 10 V m 80 MHz to 1000MHz 80 AM 1 kHz 35 V m 900 MHz Frequency 200 kHz D...

Page 16: ...ock IEC 60068 2 27 IEC 60255 21 2 Class 1 Seismic vibration IEC 60068 3 3 IEC 60255 21 3 Class 2 sinusoidal 5 Hz to 150 Hz Amplitude 7 5 mm under 8 Hz acceleration 20 m s2 2 g beyond 8 Hz Frequency sweep rate 3 each at 90o 20 cycles per axe semi sinusoidal acceleration 5 g duration 11 ms every 3 shocks in both directions of the 3 axes sinusoidal 1 Hz to 8 Hz 8 mm Amplitude horizontal axe 1 Hz to 8...

Page 17: ...0255 21 2 Class 1 Shock IEC 60068 2 29 IEC 60255 21 2 Class 1 sinusoidal 5 Hz to 8 Hz 7 5 mm amplitude 8 Hz to 150 Hz 2 g acceleration Frequency sweep rate 1 octave min 20 cycles in 3 axes orthogonal semi sinusoidal Acceleration 15 g duration 11 ms every 3 shocks in both directions of the 3 axes semi sinusoidal Acceleration 10 g duration 16 ms every 1000 shocks in both directions of the 3 axes ...

Page 18: ...C53000 B1140 C602 1 Seite 18 von 20 Operating Instructions 7XV5810 0xA00 2 4 Dimension Drawings Figure 1 Dimension Drawings in mm ...

Page 19: ...control relay K1 1 break contact L1 L Power supply Vaux AC L1 DC L N L Power supply Vaux AC N DC L Table 1 Connection terminals for the 24 V wide range power supply 2 6 Connection terminals 7XV5810 0CA00 5 V Terminal Description Connection 0V Output voltage VA Consumer 3 W 5V Output voltage VA Consumer 3 W 1 Voltage control relay K1 1 break contact 2 Voltage control relay K1 1 break contact L1 L P...

Page 20: ...40 C602 1 Seite 20 von 20 Operating Instructions 7XV5810 0xA00 2 7 Ordering Data Name Ordering Nr Wide range power supply 7 X V 5 8 1 0 0 A 0 0 24 V B 5 V C Table 3 Ordering Data of the wide range power supplies ...

Reviews: