INSTALLATION AND CONFIGURATION
2-40
Document No.: COM-00-05-16 June 2006, Revised June 2014
Version: C.1
2.6.25
Genisys Poll Starting Station
The Genisys poll starting station is used when the serial interface is configured for Genisys ATCS
Office. It designates the starting station number to poll.
The default value is 1.
To set the Genisys Poll Starting Station:
1.
On the Second Configuration Menu, select “Genisys Poll Starting Station” to be changed. The
Change Genisys Starting Station Polling Number screen appears.
Figure 2-55. Change Genisys Starting Station Polling Number Screen
2.
To keep the starting station number setting, press
ENTER
. To change the starting station
number setting, enter the new value and then press
ENTER
.
Entry can be any value from 0 to
64.
The user will be returned to the Second Configuration Menu.
3.
Prior to exiting the First Configuration Menu, select “Save changes then restart” to save
changes and restart the WAG.
2.6.26
Genisys Poll Ending Station
The Genisys poll ending station is used when the serial interface is configured for Genisys ATCS
Office.
It designates the ending station number to poll.
The default value is 16.
To set the Genisys Poll Ending Station:
1.
On the Second Configuration Menu, select “Genisys Poll Ending Station” to be changed. The
Change Genisys Ending Station Polling Number screen appears.