Connection
4.2 Wiring connection block ECOFAST
ASM 456 interface module
Operating Instructions, 07/2015, J31069-D0162-U001-A6-7618
21
4.2
Wiring connection block ECOFAST
Properties
●
Connect up the supply voltages and PROFIBUS DP on the ECOFAST connection block
using an ECOFAST connector plug.
●
You can loop the supply voltages and PROFIBUS DP through via another ECOFAST
connector plug.
●
The first and last ASM 456 (consumer) on the PROFIBUS DP must be terminated with
the terminating resistor.
Requirements
You have set the PROFIBUS address (according to your project).
Required tools
Screwdriver, stripping and crimping tool for wiring the ECOFAST connector plug, if you are
not using pre-assembled ECOFAST connector plugs.
Accessories required
●
Pre-assembled ECOFAST hybrid cable with ECOFAST connector. The cable is available
in different lengths.
●
If you are not using a pre-assembled ECOFAST hybrid cable (see table below):
–
Han Brid Cu cable connector and/or Han Brid Cu cable socket
–
ECOFAST hybrid cable
●
Terminating resistor (ECOFAST) for PROFIBUS DP
●
For order numbers, refer to "Ordering data" section.