background image

Building Technologies 

Fire Safety & Security Products

 
 

 

 

CHSL4010 
CHSL4011 
Large Camera Housing 

Installation Guide 

 

Summary of Contents for CHSL4010

Page 1: ...Building Technologies Fire Safety Security Products CHSL4010 CHSL4011 Large Camera Housing Installation Guide ...

Page 2: ...document and in the subject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him ...

Page 3: ...ymbols 6 2 EU Directives 7 3 Technical data 8 3 1 Specifications 8 3 2 Mechanical dimensions 9 3 3 Key to Parts 9 4 Scope of delivery 10 5 Mounting 11 5 1 Adjusting the Sunshield 11 5 2 Accessing the inside of the Housing Enclosure 11 5 3 Mounting the Camera and Lens Assembly 12 5 4 Mounting the Camera Housing Assembly 13 5 5 Connecting to the Power Supply 14 6 Maintenance and service 16 7 Disposa...

Page 4: ......

Page 5: ...lso take into account any additional country specific local safety standards or regulations concerning project planning operation and disposal of the product z It is recommended that all preparatory work e g fitting of accessories be carried out in a workshop prior to final installation Liability claim z Do not connect the device if it is damaged or any parts are missing z Do not make any changes ...

Page 6: ... severity of a hazard is indicated by the following written warning notices Signal word Type of hazard CAUTION There is a risk of minor to medium injuries or damage to property IMPORTANT Malfunctioning may result 1 4 Meaning of the hazard symbols The nature of the hazard is indicated by icons Warning of a hazard ...

Page 7: ...mbH Co oHG 76181 Karlsruhe Germany EU Directive 2004 108 EC on electromagnetic compatibility Conformity with the European Directive 2004 108 EC is demonstrated by compliance with the following standards Emitted interference EN 61000 3 2 EN 61000 3 3 EN 55022 Class B Resistance to interference EN 50130 4 EU Directive 2006 95 EC Low Voltage Directive Compliance with the European Directive 2006 95 EC...

Page 8: ... Environmental Operating Temperature 20 to 60 C 20 to 40 C when wiper kit fitted Ensure fitted equipment has suitable temperature range for the application e g maximum typical ambient operating temperature of camera and lens Ta 40 C Maximum internal dissipated power 50 W 25 W including wiper motor when wiper kit fitted Relative humidity Up to 95 non condensing Weatherproof rating IP66 BS EN 60 529...

Page 9: ...nical dimensions 1 168 mm 2 143 mm 3 82 5 mm 4 100 mm 5 155 mm 6 627 mm 7 609 mm 8 559 mm 9 596 mm 10 149 mm 3 3 Key to Parts 1 2 3 4 5 6 7 9 8 10 Fig 2 Key to Parts 1 Front End Cap 6 Cable Anchor 2 Housing Body 7 Terminal Board 3 Sunshield 8 Camera Mounting Plate 4 Rear End Cap 9 Demister Assembly 5 Cable Glands 10 Window ...

Page 10: ...m thick z Spacer block 3 mm thick z Spacer block 6 3 mm thick z 3 mm across flats ALLEN key z Shoulder washer to insulate screw from camera mounting plate NOTE The complete assembly should be mounted and tested in the workshop prior to use on site Accessories Type Designation CAHL4010 WK 230 V AC Wiper Kit CAHL4011 WK 24 V AC Wiper Kit CAHL401X WK Spare Wiper Arm Assembly CAHL4010 WU 230V AC Washe...

Page 11: ...de of the Housing Enclosure 1 Using the ALLEN key provided loosen but do not completely remove the 4 securing screws A See Fig 4 2 Slide the housing cover forwards B 3 Disconnect the earth wire from the terminal board C 4 Allow the cover to pivot at the end or twist to completely remove D NOTE To re assemble carry out steps 1 to 4 in reverse making sure the earth wire is reconnected The screws whi...

Page 12: ...ng The nylon shoulder washer can be used on the mounting screw for the camera to insulate it from the housing 5 Use the spacers provided to adjust the height of the camera and lens on the plate the lens should be centralised on and close to the window glass when mounted in the housing 6 Reattach the plate D following Steps 1 to 3 in reverse 7 Wire the camera and lens as described in the manufactur...

Page 13: ...apped holes on a 101 6mm 4 PCD for mounting the camera housing to a bracket Ensure the screws used to mount the housing to a bracket do not bottom out in the mounting holes by being too long 1 Screw the mounting bracket to the base of the unit A see Fig 6 2 Secure the assembly following the bracket installation instructions Fig 6 Mounting the Camera Housing Assembly ...

Page 14: ...010 110 230 V AC units and 5 A for CHSL4011 12 24 V AC units NOTE Use only cable suitable for the application and that meets the standards required by the installation The conductor size for power cable s must be at least 0 75 mm 2 The maximum recommended conductor size is 1 5 mm 2 1 Select the most suitable cable gland entry see section 3 1 for sizes and remove the blanking plug supplied in the g...

Page 15: ...s 09 2008 Fig 8 Terminal board connection details 1 Ancillary Connections Block 2 Fused Output 3 Earth Gnd 4 Input Supply Terminal 5 Fuse F1 2 A 250 V AC 5x20 Type T HBC for T462 5 A 250 V AC 5x20 Type T HBC for T463 6 Heater Output pre wired and connected through fuse F1 ...

Page 16: ... the required information from your local Siemens office We must also point out that the contents of this installation guide do not constitute a part of an earlier or existing agreement Neither do they constitute or amend any earlier or existing commitment or legal relationship All obligations on the part of Siemens result from the relevant purchase agreement which also contains the complete and s...

Page 17: ......

Page 18: ...rity Products GmbH Co oHG D 76181 Karlsruhe www buildingtechnologies siemens com 2008 Copyright by Siemens Building Technologies Data and design subject to change without notice Supply subject to availability Document no A6V10087715 Edition 10 09 2008 ...

Reviews: