Button 3
Checks the non-volatile memory (non destructively). If suc-
cessful a confirm tone is given or if unsuccessful an error
tone is given. The unit returns to test mode with the green
LED continuously lit.
Button 4
Fires the solenoid in and out every 4 seconds, the status
of reed switch sensor is given on the LEDs, with contact
locked given by the green LED and unlocked given by the
red LED.
Button 5
Puts the unit into sleep mode to enable the current con-
sumption of the unit to be measured. The unit will come
out of this function when any key is pressed.
Button 6
Only shows the status of the position sensor. Red LED
– unit locked (solenoid un-engaged), green LED - unit
unlocked (solenoid engaged).
Button 7
Puts the unit into an unlocked state with the status of the
position sensor shown on the LEDs as previously stated.
Button 8
Shows the status of the low battery input. Low battery
detected the red LED will show. If the battery voltage is OK
the green LED will show.
Button 9
Does nothing except beep and light the red LED.
Button *
Does nothing except beep and light the red LED.
Button 0
Does nothing except beep and light the red LED.
Button #
Exits test mode with a confirm tone, leaving all the data
intact in the non-volatile memory.
Reset button
on rear
By pressing and holding the reset for 2 seconds the Co-
door’s memory is cleared back to factory settings:
No programming code set.
No access codes set.
Buzzer enabled.
Deactivation function enabled.
•
•
•
•
NoTE!
The reset function can only be used when in test mode!