background image

 

Hardware installation 

 

3.3 Hardware compatibility 

CP 5613 A3 / CP 5614 A3 
Operating Instructions, 10/2012, C79000-G8976-C277-01 

19

 

3.3

 

Hardware compatibility 

Compatibility with predecessor versions   

The CP 5613 A3 can replace the following predecessor versions: 

 

CP 5613 A2 

 

CP 5613 

The CP 5614 A3 can replace the following predecessor versions: 

 

CP 5613 A2 and CP 5614 A2 

 

CP 5613 and CP 5614 

 

 

Note 
No configuration changes necessary 
You can adopt the configuration of the previous CP. To do this, you simply need to reload 

the configuration. 

 

Procedure for replacement    

When replacing a module, follow the steps described in the section "Hardware installation 

(Page 17)". 

Summary of Contents for CP 5613 A3

Page 1: ...__ ___________________ ___________________ ___________________ SIMATIC NET PG PC PROFIBUS CP 5613 A3 CP 5614 A3 Operating Instructions 10 2012 C79000 G8976 C277 01 Preface Description of the device 1 Software installation 2 Hardware installation 3 Configuration 4 Technical specifications 5 Approvals A ...

Page 2: ...ant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in t...

Page 3: ...2 CP 5614 A3 order number 6GK1 561 4AA02 Content of this documentation These operating instructions contain information about the installation and configuration of the 5613 A3 and CP 5614 A3 communications processors Updated operating instructions on the Internet You will find the current version of these operating instructions on the Product Support pages under the following entry ID 58826514 htt...

Page 4: ...ware This document contains detailed information on installing the SIMATIC NET PC software Entry ID 42784913 http support automation siemens com WW view en 42784913 System manual PROFIBUS Network Manual In this document you will find detailed information about setting up a PROFIBUS network Entry ID 35222591 http support automation siemens com WW view en 35222591 SIMATIC NET documentation You will ...

Page 5: ...dll func cslib csinfo lang en ob jid 38718979 caller view You will find contact data on the Internet at the following address http www automation siemens com partner guiwelcome asp lang en SITRAIN Siemens training for automation and industrial solutions With over 300 different courses SITRAIN covers the entire Siemens product and system spectrum in the field of automation and drive technology Adva...

Page 6: ...Preface CP 5613 A3 CP 5614 A3 6 Operating Instructions 10 2012 C79000 G8976 C277 01 ...

Page 7: ...es of the CP 5614 A3 10 1 3 PROFIBUS interface 11 1 4 Meaning of the LED display 13 2 Software installation 15 2 1 Installing the SIMATIC NET PC software 15 2 2 Uninstalling the SIMATIC NET PC software 15 3 Hardware installation 17 3 1 Safety notices 17 3 2 Installing hardware 18 3 3 Hardware compatibility 19 4 Configuration 21 5 Technical specifications 23 A Approvals 25 Index 27 ...

Page 8: ...Table of contents CP 5613 A3 CP 5614 A3 8 Operating Instructions 10 2012 C79000 G8976 C277 01 ...

Page 9: ...ers up to 124 nodes can be connected The additional interface signals for a direct link to a PLC Programmable Logic Controller are supported up to 187 5 Kbps Installation in PGs and PCs with a PCI slot The following is supported PCI 33 MHz 66 MHz 32 bits 64 bits Plug and play Optimized for fast DP master operation DP Base with up to 124 DP slaves with full data consistency Relief of the PC PG with...

Page 10: ... CP 5614 A3 Properties The CP 5614 A3 is a communications processor for connecting PCs personal computers or PGs programming devices to PROFIBUS and MPI networks In addition to the properties of the CP 5613 A3 the CP 5614 A3 also has the following features Additional PROFIBUS connection as DP slave to a second DP network DP master and DP slave can be operated at the same time Program controlled da...

Page 11: ...3 3 3 1 LEDs 2 PROFIBUS interface PB1 master only 3 PROFIBUS interface PB2 slave only 1 3 PROFIBUS interface Note Connector with 180 cable outlet Use the bus connector with a 180 cable outlet if you want to use the lower PROFIBUS connector PB2 slave only or both PROFIBUS connectors at the same time You can obtain these connectors for example under the following order numbers 6GK1 500 0FC10 6GK1 50...

Page 12: ... Socket pin 2 is not connected With other MPI DP components the return line of the floating 24 V power supply may be via this pin 3 LTG_B Signal line B of the PROFIBUS connector Input output 4 RTSAS RTSAS input signal for direct MPI link The control signal is 1 active when the automation system connected over a special MPI cable is sending Input 5 M5EXT M5EXT return line GND of the 5 V power suppl...

Page 13: ...ration Green flashes at one second intervals Bad database Green flashes fast yellow is off Module not started normal status following reset Green and yellow flashing alternately When using more than one module in a PG PC Identification of the module by a diagnostics tool Green and yellow flashing synchronized Exception status error in firmware One of the two LEDs is on the second flashes quickly E...

Page 14: ...Description of the device 1 4 Meaning of the LED display CP 5613 A3 CP 5614 A3 14 Operating Instructions 10 2012 C79000 G8976 C277 01 ...

Page 15: ...ed in the installation manual SIMATIC NET PC Software You will find this installation manual on the Product Support pages under the following entry ID 42784913 http support automation siemens com WW view en 42784913 You should also note the current information on the SIMATIC NET PC software on the product support pages under the entry ID 12660737 http support automation siemens com WW view en 1266...

Page 16: ...e entire SIMATIC NET PC software on the PG PC not only the driver for the communications processor Uninstall the entire software package as described and recommended in the installation manual SIMATIC NET PC Software You will find the installation manual on the SIMATIC NET DVD or on the Product Support pages under the following entry ID 42784913 http support automation siemens com WW view en 42784...

Page 17: ...ly sensitive devices ESD Pick up components and modules only by their edges Do not touch the pins or conductors Before opening the PG PC make sure that you discharge any electrostatic charge from your body You can do this by touching metal parts on the back panel of the PG PC pulling the power plug Make sure that you also discharge any electrostatic charge from tools you intend to use for the work...

Page 18: ...re Note First install the software First install the software before you insert the CP in the slot Activated plug and play function The plug and play function must be activated in the BIOS of your PG PC Follow the steps outlined below when inserting the CP 1 Turn off your PG PC and pull the power cable connector 2 Open the computer housing as described in the manual accompanying your PG PC 3 Remov...

Page 19: ...following predecessor versions CP 5613 A2 CP 5613 The CP 5614 A3 can replace the following predecessor versions CP 5613 A2 and CP 5614 A2 CP 5613 and CP 5614 Note No configuration changes necessary You can adopt the configuration of the previous CP To do this you simply need to reload the configuration Procedure for replacement When replacing a module follow the steps described in the section Hard...

Page 20: ...Hardware installation 3 3 Hardware compatibility CP 5613 A3 CP 5614 A3 20 Operating Instructions 10 2012 C79000 G8976 C277 01 ...

Page 21: ...ng configuration If there is not yet a CP 5613 A3 CP 5614 A3 available in the hardware catalog of your STEP 7 version or NCM PC version you can also select one of the following CPs for configuration CP 5613 A2 CP 5614 A2 CP 5613 CP 5614 The CP 5613 A3 CP 5614 A3 is downwards compatible with the configurations of the previous versions CAUTION The DP slave configuration of a CP of the 5613 series is...

Page 22: ...Configuration CP 5613 A3 CP 5614 A3 22 Operating Instructions 10 2012 C79000 G8976 C277 01 ...

Page 23: ...PG PC PCI 33 MHz 66 MHz 32 bit signal voltage 5 VDC or 3 3 VDC V 2 2 plug and play Electrical specifications of the PCI plug in connector Rated voltage 3 3 VDC and 12 VDC Permitted range 3 0 to 3 6 VDC 11 0 to 13 0 VDC Operating voltage Properties Safety extra low voltage SELV to EN 60950 Current consumption Typical For CP 5613 A3 For CP 5614 A3 150 mA at 3 3 V and 250 mA at 12 V 180 mA at 3 3V an...

Page 24: ...cceleration 10 axis Shock operating EN 60068 2 27 Half sine Time Number of shocks 50 m s2 5 g 30 ms 100 axis Design dimensions and weight Module format Flat module Short PCI card Weight For CP 5613 A3 For CP 5614 A3 98 g 113 g Dimensions W x H x D For CP 5613 A3 For CP 5614 A3 18 x 107 x 125 18 x 107 x 125 Electromagnetic compatibility Emission to EN 55022 to FCC Class B Class B On signal cables S...

Page 25: ...y You will find the EC declaration of conformity for the communications processor on the Product Support pages under the following entry ID For the CP 5613 A3 58826788 http support automation siemens com WW view en 58826788 For the CP 5614 A3 58826997 http support automation siemens com WW view en 58826997 Machinery directive This communications processor is not a machine in the sense of the EC di...

Page 26: ...t does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to...

Page 27: ...nfiguration compatibility 21 Converting 19 D Documentation on the Internet 3 D sub female connector 12 E Electric shock 17 Electrostatic charge 17 ESD directives 17 L LEDs 13 M Mounting 17 N NCM PC 21 Number of CPs permitted 18 O Oblique installation position 17 P PIN assignment 12 PROFIBUS network 12 R Replacing 19 S SIMATIC NET documentation 4 STEP 7 21 ...

Page 28: ...Index CP 5613 A3 CP 5614 A3 28 Operating Instructions 10 2012 C79000 G8976 C277 01 ...

Reviews: