In just a few steps to the first project
1-10
System- and communication configuring D7-SYS - SIMADYN D
Edition 12.2001
1.5
Testing, compiling and downloading the project
1.5.1
Checking the project consistency and compiling
Step
Procedure
Result
26
Start the consistency check of your project
with
Chart > Check consistency > Charts as
program
, then
OK
.
Acknowledge
the dialog window or evaluate
the error messages via
Details
.
The result is displayed in the dialog window.
27
Start to compile the project after a successful
consistency check with
Chart > Compile > Charts as program
,
then
OK
.
Acknowledge
the dialog window or evaluate
the error messages using
Details
.
The result is displayed in a dialog window.
You have created your first user project.
1.5.2
Downloading the user project into the SIMADYN D-CPU module
SIMADYN D allows you to
•
download online or
•
offline.
Maybe you do not have a connection from your PC/PG to the SIMADYN
D station, which is why you can use the possibility of downloading into a
memory module.
Step
Procedure
Result
28
Select
Target system > Download
.
You will obtain a dialog window with options.
29
Select "User program" and "Offline"
Insert the memory module into the PCMCIA
slot of the PG/PC.
Start to download with
OK
.
A progress display shows how the system
and your user program are being
downloaded into the memory module.
30
Insert the memory module into the SIMADYN
D station and re-start it.
Your user program is then started.
Introduction
Downloading