36
2. Function
The
DELTA i-system shutter control timer is a component of the shutter control system
and is installed in combination with the
shutter control insert without extension in a flush-
mounting box as per DIN 49307 (deep box recommended). The device permits
programmable and time-controlled switching of a blind/shutter motor up to 1000 W. The
motor used must be equipped with end position limit switches (electronic or mechanical).
Product features overview:
w
Simple operation with four keys
w
Three program memories for a total of up to 18 switching times
(e. g. nine UP and nine DOWN times).
w
Factory-programmed switching times in two program memories (
A
,
B
)
w
Random function
w
Astro function
w
Individual Astro function with Astro time shift.
w
Random and Astro functions can be combined
w
Summer/winter time switching by depression of a key
w
Individual motor operating times presettable
w
Running reserve:
Programmed switching times are permanently safe.
Actual data (time, month, date, day) safe up to 24 hours (no attendance and no
back-up batteries required).
w
Sun protection function
w
Twilight function
Function
GB