Document No: IOM-002
Issue Date:
24/09/2020
Revision:
6
Page:
31 of 42
Unrestricted
Dummy and Parking Connectors
Figure 18
Typical flange mounted dummy and parking connectors
Installation of flange mounted dummy connectors is the same procedure as for non-dummy
connectors, so please follow the installation instructions in the relevant sections.
Testing of connectors
For testing of products in a dry environment (topside) The appropriate test connector must always
be used to make electrical contact during testing.
For testing connectors in a wet environment, a standard subsea connector must be used. Siemens
connectors should not be used as pressure barrier in a pressure vessel, they are not intended for
this use.
If present, guide pins must never be removed from test connectors as this can lead to damage and
will invalidate the connector warranty.
Danger!
Risk of imminent danger to life or risk of severe personal injury.
Sudden release of stored pressure.
DigiTRON products are not intended for use as a penetration for fixed top-side or land-
based pressure vessels. They are not designed to comply with the requirements of the
Pressure Equipment Directive (2014/68/EU). They are intended for integration into
subsea equipment only.
All pressure testing of DigiTRON product must be undertaken by a competent person.
Danger!
Risk of death from electric shock from a damaged test connector
-
Never hold a test connector while electrically energised
-
Do not use a test connector if it appears damaged in any way.
Danger!
Risk of death from electric shock from improper use of test connector. Never
disassemble test connectors. In particular, removal of the rubber termination sleeves
placed over the joint between the cable and the test connector is prohibited, as this may
expose live parts to the user.
-
Never disassemble a test connector
Caution.
Risk of material damage. The appropriate test connector must always be used
to make electrical contact during testing. Under no circumstances should a foreign object
(such as a screwdriver, test probe or crocodile clip) be used as a test connection as this
could damage the seals and insulation. Such actions will invalidate the product warranty.