background image

5

Building Technologies
Fire Safety

Technical data DM1101 / DM1103 / DM1104

DM1101

DM1103 / DM1104

Operating voltage

DC 16…26 V

DC 16…26 V

Max. current, permanent

60 mA

60 mA

Max. pulsed current

100 mA

100 mA

Terminal block

0.28…1.5 mm

2

0.28…1.5 mm

2

Operating temperature

-25…+70 °C

-25…+70 °C

Storage temperature

-30…+75 °C

-30…+75 °C

Humidity (no condensation)

95 % rel.

95 % rel.

Connection factor KMK

1

1

Color

red, ~RAL 3000 / blue, ~RAL 5005

yellow, ~RAL 1023 / green, ~RAL 6024

red, ~RAL 3000 / blue, ~RAL 5005

yellow, ~RAL 1023 / green, ~RAL 6024

Protection category IEC 60529

with seal DMZ1197-AD

IP44

IP41
IP65

Standards

EN 54-11

EN 54-11

Approvals

VdS

LPCB

DM1101


DM1103

G295036

DM1104

G299068

531j/02

System compatibility

Compatible to all fire detection system control units

with collective/SynoLINE600 detector evaluation

Siemens Schweiz AG; Theilerstrasse 1a

CH-6300 Zug

Technical data: see doc.

007980

08

DM1101 - Manual callpoint for use in fire detection and fire alarm systems installed in buildings.

305/2011/EU (CPR): EN 54-11 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3

The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is

obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download

DoP No.: 0786-CPR-20498; DoC No.: CED-DM1101

0786

DM1101

Siemens Schweiz AG; Theilerstrasse 1a

CH-6300 Zug

Technical data: see doc.

001720

08

DM1103 - Manual callpoint for use in fire detection and fire alarm systems installed in buildings.

305/2011/EU (CPR): EN 54-11 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581

The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is

obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download

DoP No.: 0786-CPR-20499; DoC No.: CED-DM1103

0786

DM1103

Siemens Schweiz AG; Theilerstrasse 1a

CH-6300 Zug

Technical data: see doc.

001721

08

DM1104 - Manual callpoint for use in fire detection and fire alarm systems installed in buildings.

305/2011/EU (CPR): EN 54-11 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581

The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is

obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download

DoP No.: 0786-CPR-20500; DoC No.: CED-DM1104

0786

DM1104

Summary of Contents for DM1101

Page 1: ...ive SynoLINE600 l Manual call point to all fire detection system control units with collec tive SynoLINE600 detector evaluation l Manual call point DM1101 with direct operation l Manual call point DM1103 with indirect operation and DM1104 with direct operation l Manual release button DM1103 L and emergency stop button DM1103 S for gas extinguishing system l Two wire installation ...

Page 2: ...over l Function Direct alarm actuation by pushing in the glass plate By replacing the glass plate the push button is set back and the device is ready for operation again l Application For the immediate manual actuation of an alarm For indoor and outdoor application For surface and recess mounted feed lines in easily accessible places Manual call point DM1103 DM1104 A protective cover DMZ1197 AC ac...

Page 3: ...y protects the manual release and emer gency stop button from unintentional glass break A seal DMZ1197 AD accessory protects the manual release and emergency stop but ton in wet applications Seal Protective cover l Function DM1103 L Indirect extinguishing release by pushing in the glass plate and pressing the push button To replace the glass plate open the housing door with the key The push button...

Page 4: ...o the DM1101 a hole must be drilled into the top or bottom of the detector housing marking use at max cable gland M20 For surface mounted feed lines to the DM1103 DM1103 x DM1104 the housing is equipped with opening at the top and bottom with sealing studs for M20 cable glands or locking plug Dimensions DM1101 87 46 6 87 DM1103 DM1103 L S DM1104 43 2 134 3 134 3 ...

Page 5: ...e DoP and the EU Declaration of Conformity DoC which is obtainable via the Customer Support Center Tel 49 89 9221 8000 or http siemens com bt download DoP No 0786 CPR 20498 DoC No CED DM1101 0786 DM1101 Siemens Schweiz AG Theilerstrasse 1a CH 6300 Zug Technical data see doc 001720 08 DM1103 Manual callpoint for use in fire detection and fire alarm systems installed in buildings 305 2011 EU CPR EN ...

Page 6: ...43 Key with cover 0 030 kg DM1103 DM1104 DMA1192 AA BPZ 5222870001 Housing red with glass and key 0 256 kg DMA1192 AB BPZ 5464250001 Housing blue with glass and key 0 256 kg DMA1192 AC BPZ 5464120001 Housing yellow with glass and key 0 256 kg DMA1192 AD BPZ 5090190001 Housing green with glass and key 0 256 kg DMA1103D A5Q00004470 Switching unit to DM1103 0 067 kg DMA1104D A5Q00005925 Switching uni...

Page 7: ...device for use in fire detection and fire alarm systems installed in buildings 305 2011 EU CPR EN 12094 3 2014 30 EU EMC EN 50130 4 EN 61000 6 3 2011 65 EU RoHS EN 50581 The declared performance and conformity can be seen in the Declaration of Performance DoP and the EU Declaration of Conformity DoC which is obtainable via the Customer Support Center Tel 49 89 9221 8000 or http siemens com bt down...

Page 8: ... 0 344 kg EMERGENCY STOP complete for gas extin guishing system DM1103 S A5Q00014486 Housing blue DMA1192 AB switching unit spec self reset inscription plate EMERGENCY STOP gas extinguishing system 2 locking plugs M20 x 1 5 2 holes 0 350 kg Accessories DMZ1197 AC BPZ 5223550001 Protective cover 0 012 kg DMZ1197 AD BPZ 5470680001 Seal for wet areas 0 023 kg A5Q00004478 Metal screwed cable gland M20...

Reviews: