10/2003
Settings
Operating Instructions SRIF 2002
Page 25 of 33
4.2
Settings for the operation in the MDA / SDA
For the operation in the MDA / SDA, both an organization channel (plus stand-by
channel) and a data channel are required. The organization channel is the same
for all MDA /SDA within one spacial area.
The following channel numbers are the standard / factory settings for the
SRIF 2002 module:
Organization channel:
68
Stand-by organization channel:
41
Note
No settings can be carried out on the SRIF! The information given above is only
relevant for MDA applications.
Due to the increased power consumption of the SRIF 2002 module, the increased
power consumption is set for new MDAs in the operating mode “Constant current
control = ON” (MDA 5 = 280 mA and MDA6 = 300 mA).
Please contact your contact partner for more information.
4.3
Settings for the operation in the hand-held terminal
Depending on the version and the equipped firmware in the hand-held terminal, it
is possible that not all of the radio channels can be set and thus used.
Limitations of the radio channels between 1 and 33 and 41 to 73 might occur. This
has to be taken into account when planning the installation.
In the case of older firmware versions, the possible HEX-coded channels cannot be
set either.
The increased power consumption of the SRIF 2002 modules reduces the service
life of the battery-operated handheld terminal.