Operating Instructions SRIF 2002
Page 29 of 33
Technical Data
6
●
Transmit / receive frequency
5,726.0866 MHz up to
5,873.9134 MHz
also see the frequency table
(Chapter 7, page 31).
●
Transmitting
power
PWR = open
PWR = GND
+7 dBm up to +13 dBm
–9 dBm up to –2 dBm
●
Signal band width
normally: 1100 kHz
●
FSK frequency shift
normally: 120 kHz
●
Input
sensitivity
–96
dBm
●
Channel separation
1,173.23 kHz
●
Operating voltage
4.5 V up to 5.5 V
●
Current
consumption
in operation
in stand-by
145 mA up to 210 mA
17 mA up to 23 mA
●
Voltage at Rx/Tx, SerIN, TxD, mode
-0. 3 V up to +6.5 V
●
Voltage at A0..A6, PWR
-0.3 V up to +4.5 V
●
Operating temperature range
-10 °C up to +65 °C
●
Storage temperature range
-40 °C up to +85 °C
●
Size
100 x 47 x 11 mm
Subject to technical changes.