Nozzle table
REGULATION OF MINIMUM FROM NG TO LPG
1. Light the burner and turn the knob to the
minimum position.
2. Remove the knob from the tap
3. Introduce a small screwdriver in hole B
(picture
6) and tighten the adjusting screw
completely (taking care not to turn the shaft of
the tap).
Check that when passing quickly from the maximum
position to the minimum the flame does not go out.