Copyright © Siemens AG 2016. All rights reserved
100
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
Description:
Edge Select Register
Select the edge for the interrupt detection
(only when edge detection has been set for the associated input)
Interrupt inputs 0 – 7
0 = Interrupt detection for positive edge
1 = Interrupt detection for negative edge
Register:
SWIRREG0
Address:
9500h
Bits:
7dt0
Reset value:
00h
Attributes:
rh w
Description:
Software Interrupt Register
Specification of interrupt requests
Interrupt inputs 0 – 7
0 = No interrupt request
1 = Set interrupt request
Register:
PRIOREG0
Address:
A000h
Bits:
2dt0
Reset value:
7h
Attributes:
r
w
Description:
Priority Register for IRQ0, the higher the number, the lower the priority
Register:
PRIOREG1
Address:
A004h
Bits:
2dt0
Reset value:
7h
Attributes:
r
w
Description:
Priority Register for IRQ1, the higher the number, the lower the priority
Register:
PRIOREG2
Address:
A008h
Bits:
2dt0
Reset value:
7h
Attributes:
r
w
Description:
Priority Register for IRQ2, the higher the number, the lower the priority
Register:
PRIOREG3
Address:
A00Ch
Bits:
2dt0
Reset value:
7h
Attributes:
r
w
Description:
Priority Register for IRQ3, the higher the number, the lower the priority
Register:
PRIOREG4
Address:
A010h
Bits:
2dt0
Reset value:
7h
Attributes:
r
w
Description:
Priority Register for IRQ4, the higher the number, the lower the priority
Register:
PRIOREG5
Address:
A014h