Register:
FIQ_SEL_4
Address:
48010h
Bits:
6dt0
Reset value:
00h
Attributes:
r
w
Description:
Selects one of the IRQs as input to FIQ processing.
Important: The FIQ_SEL register have to be configured with different val-
ues (except 0) for each select register. The ICU does not take care at all
about this issue.
Register:
FIQ_SEL_5
Address:
48014h
Bits:
6dt0
Reset value:
00h
Attributes:
r
w
Description:
Selects one of the IRQs as input to FIQ processing.
Important: The FIQ_SEL register have to be configured with different val-
ues (except 0) for each select register. The ICU does not take care at all
about this issue.
Register:
FIQ_SEL_6
Address:
48018h
Bits:
6dt0
Reset value:
00h
Attributes:
r
w
Description:
Selects one of the IRQs as input to FIQ processing.
Important: The FIQ_SEL register have to be configured with different val-
ues (except 0) for each select register. The ICU does not take care at all
about this issue.
Register:
FIQ_SEL_7
Address:
4801Ch
Bits:
6dt0
Reset value:
00h
Attributes:
r
w
Description:
Selects one of the IRQs as input to FIQ processing.
Important: The FIQ_SEL register have to be configured with different val-
ues (except 0) for each select register. The ICU does not take care at all
about this issue.