Copyright © Siemens AG 2016. All rights reserved
141
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
fer List (0-255)
Register:
GDMA_JOB16_CTRL
Address:
50h
Bits:
31dt0
Reset value:
00000000h
Attributes: (r) (w)(t)
Description:
Job Control Registers 16
Bit
Identifier
Reset
Attr. Function
/
Description
0dt0 SW_JOB_START
0h
t
Start Job from SW
0 = don’t care, 1 = Start
1dt1 JOB_EN
0h
r w
Job Enable
0 = disable, 1 = enable
2dt2 HW_JOB_START_EN
0h
r w
Start Job by Hardware
0 = disable, 1 = enable
3dt3 HW_FLOW_EN
0h
r w
Hardware Triggered Flow Enable
0 = disabled, 1 = enabled
4dt4 INTR_EN
0h
r w
Interrupt Request Generation Enable
0 = disabled, 1 = enabled
5dt5 JOB_RESET
0h
r w
Reset Job (cancel running job)
0 = don’t care, 1 = Cancel
7dt6 <notused>
0h
r
all bits
= '0'
13dt8 HW_SELECT
00h
r w
HW Job Start Selector (selects one from
64 inputs)
15dt14 <notused>
0h
r
all bits
= '0'
20dt16 JOB_PRIO
00h
r w Job Priority (0-31)
23dt21 <notused>
0h
r
all bits
= '0'
31dt24 TRANSFER_PTR
00h
r w
First Transfer Number of Job in Trans-
fer List (0-255)
Register:
GDMA_JOB17_CTRL
Address:
54h
Bits:
31dt0
Reset value:
00000000h
Attributes: (r) (w)(t)
Description:
Job Control Registers 17
Bit
Identifier
Reset
Attr. Function
/
Description
0dt0 SW_JOB_START
0h
t
Start Job from SW
0 = don’t care, 1 = Start
1dt1 JOB_EN
0h
r w
Job Enable
0 = disable, 1 = enable
2dt2 HW_JOB_START_EN
0h
r w
Start Job by Hardware
0 = disable, 1 = enable