3dt0 SPI_Length
0h
r w SPI_Length
31dt4 reserved
0h
Register:
SPI_InMode
Address: 39Ch
Bits:
31dt0
Reset value:
0h
Attributes:
r w
Description:
SPI_InMode
Bit
Identifier
Reset
Attr. Function / Description
0dt0 InTransfer_Mode
0h
r w InTransfer_Mode
1dt1 InTransfer_DIR
0h
r w InTransfer_DIR
Register:
SPI_Handshake
Address: 3A0h
Bits:
31dt0
Reset value:
0h
Attributes: (r) (w)
Description:
SPI_Handshake
Bit
Identifier
Reset
Attr. Function / Description
0dt0 Handshake_Mode
0h
r w Handshake_Mode
1dt1 Busy_POL
0h
r w Busy_POL
7dt2 reserved
0h
23dt8 Wait_Time
0h
r w Wait_Time
31dt24 reserved
0h
Register:
GPIO_IOCTRL_0
Address: 400h
Bits:
31dt0
Reset value:
FFFFFFF
Fh
Attributes:
r w
Description:
GPIO_IOCTRL_0
Bit
Identifier
Reset
Attr. Function / Description
31dt0 GPIO_IOCTRL_0
FFFFFFFFh r w GPIO_IOCTRL_0
Register:
GPIO_OUT_0
Address: 404h
Bits:
31dt0
Reset value:
0h
Attributes: rh
w
Description:
GPIO_OUT_0
Bit
Identifier
Reset
Attr. Function / Description
31dt0 GPIO_OUT_0
00h
rh w GPIO_OUT_0
Register:
GPIO_OUT_SET_0