Copyright © Siemens AG 2016. All rights reserved
286
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
TIM_3_EXT_EV_1_REG
rh
w
74h
TIM_3_EXT_EV_2_REG
rh
w
78h
TIM_4_MODE_REG
(r)
(w)
80h
TIM_4_PRESCALER_REG (r)
(w)
84h
TIM_4_LOAD_REG
r
w
88h
TIM_4_COUNT_REG
r
8Ch
TIM_4_INT_EV_REG
rh
w
90h
TIM_4_EXT_EV_1_REG
rh
w
94h
TIM_4_EXT_EV_2_REG
rh
w
98h
TIM_5_MODE_REG
(r)
(w)
A0h
TIM_5_PRESCALER_REG (r)
(w)
A4h
TIM_5_LOAD_REG
r
w
A8h
TIM_5_COUNT_REG
r
ACh
TIM_5_INT_EV_REG
rh
w
B0h
TIM_5_EXT_EV_1_REG
rh
w
B4h
TIM_5_EXT_EV_2_REG
rh
w
B8h
GATE_TRIG_CONTROL_REG (r)
(w)
C0h
CLOCK_DIVIDER_REG
(r)
(w)
C4h
EXT_GATE_TRIG_MUX_REG (r)
(w)
C8h
EXT_EV_1_MUX_REG
(r)
(w)
CCh
EXT_EV_2_MUX_REG
(r)
(w)
D0h
SW_EVENT_TRIGGER_REG
(w)
D4h
2.3.10.3.9 Register Description
Module: /timer
Register:
TIM_0_MODE_REG
Address:
0h
Bits:
31dt0
Reset value:
00000000h
Attributes: (r) (w)
Description:
Timer Mode Register for Timer 0
Bit
Identifier
Reset
Attr.
Function / Description
0
INIT_BIT
0h
w
Initialization (0 =INIT_BIT not active,
1 =INIT_BIT active)