Bit
Identifier
Reset
Attr.
Function / Description
31dt0 INT_EVENT_VALUE
00000000h rh w Internal Event Value
Register:
TIM_3_EXT_EV_1_REG
Address:
74h
Bits:
31dt0
Reset value:
00000000h
Attributes: r w
Description:
Timer EXT_EVENT_1 Register for Timer 3
Bit
Identifier
Reset
Attr.
Function / Description
31dt0 EXT_EVENT_1_VALUE
00000000h rh w
Register:
TIM_3_EXT_EV_2_REG
Address:
78h
Bits:
31dt0
Reset value:
00000000h
Attributes: r w
Description:
Timer EXT_EVENT_2 Register for Timer 3
Bit
Identifier
Reset
Attr.
Function / Description
31dt0 EXT_EVENT_2_VALUE
00000000h rh w
Register:
TIM_4_MODE_REG
Address:
80h
Bits:
31dt0
Reset value:
00000000h
Attributes: (r) (w)
Description:
Timer Mode Register for Timer 4
Bit
Identifier
Reset
Attr.
Function / Description
0
INIT_BIT
0h
w
Initialization (0 =INIT_BIT not active,
1 =INIT_BIT active)
3dt1 <reserved>
0h
not used
4
CLK_INPUT_SELECT
0h
r w
Selection of Count-/Load-Clock
0 =CLK_TIMT, 1 =ext. Gate-
/Triggersignal, see also bit
GATE_EFFECT)
5
RELOAD_DISABLE
0h
r w
Reload Mode disable
0 =Reload Mode is active, 1 =Single
Mode is active
6
DIS_RLD_WHEN_WR_LDREG 0h
r w
Disable Reload when Writimg Load-
Register
0 =Reload Mode is active, 1 =Single
Mode is active
7
EXT_GATE_TRIG_ENABLE 0h
r w
Selection of Gate-/Trigger signal
0 =INT_GATE_TRIG, 1
=EXT_GATE_TRIG is Gate-/Trigger
signal