Copyright © Siemens AG 2016. All rights reserved
298
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
6
DIS_RLD_WHEN_WR_LDREG 0h
r w
Disable Reload when Writimg Load-
Register
0 =Reload Mode is active, 1 =Single
Mode is active
7
EXT_GATE_TRIG_ENABLE 0h
r w
Selection of Gate-/Trigger signal
0 =INT_GATE_TRIG, 1
=EXT_GATE_TRIG is Gate-/Trigger
signal
8
GATE_POLARITY
0h
r w
polarity of ext. Gate/Trigger signal
0 =high active/rising edge, 1 =low
active/falling edge
9
GATE_EFFECT
0h
r w
Effect of ext. Gate/Trigger signal
0 =Gate-/Count-Mode for
CLK_INPUT_SELECT =0/1,1
=Trigger-/Toggle-Mode for
CLK_INPUT_SELECT =0/1
10
TIMER_OUT_POLARITY
0h
r w
polarity of TIM_OUT
0 =high active, 1 =low active
12dt11 EVENT1_CONTROL
0h
r w
Effect of EXT_EV1 on External Event
register
13
EVENT1_INVERSION
0h
r w
Inversion of Event1
0 =not inverted, 1 =inverted
15dt14 EVENT2_CONTROL
0h
r w
Effect of EXT_EV2 on External Event
register
16
EVENT2_INVERSION
0h
r w
Inversion of Event2
0 =not inverted, 1 =inverted
31dt17 <reserved>
0h
not used
Register:
TIM_5_PRESCALER_REG
Address:
A4h
Bits:
31dt0
Reset value:
00000000h
Attributes: (r) (w)
Description:
Timer PRESCALER Register for Timer 5
Bit
Identifier
Reset
Attr.
Function / Description
7dt0 PRESCALER_VALUE
00h
r w Prescaler Value
31dt8 <reserved>
000000h not used
Register:
TIM_5_LOAD_REG
Address:
A8h
Bits:
31dt0
Reset value:
00000000h
Attributes: r w
Description:
Timer LOAD/RELOAD Register for Timer 5
Bit
Identifier
Reset
Attr.
Function / Description