Copyright © Siemens AG 2016. All rights reserved
299
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
31dt0 LOAD_RELOAD_VALUE
00000000h r w Load/Reload value
Register:
TIM_5_COUNT_REG
Address:
ACh
Bits:
31dt0
Reset value:
00000000h
Attributes: r
Description:
Timer COUNT Register for Timer 5
Bit
Identifier
Reset
Attr.
Function / Description
31dt0 COUNTER_VALUE
00000000h r Counter Value
Register:
TIM_5_INT_EV_REG
Address:
B0h
Bits:
31dt0
Reset value:
00000000h
Attributes: r w
Description:
Timer INT_EVENT Register for Timer 5
Bit
Identifier
Reset
Attr.
Function / Description
31dt0 INT_EVENT_VALUE
00000000h rh w Internal Event Value
Register:
TIM_5_EXT_EV_1_REG
Address:
B4h
Bits:
31dt0
Reset value:
00000000h
Attributes: r w
Description:
Timer EXT_EVENT_1 Register for Timer 5
Bit
Identifier
Reset
Attr.
Function / Description
31dt0 EXT_EVENT_1_VALUE
00000000h rh w External Event 1 Value
Register:
TIM_5_EXT_EV_2_REG
Address:
B8h
Bits:
31dt0
Reset value:
00000000h
Attributes: r w
Description:
Timer EXT_EVENT_2 Register for Timer 5
Bit
Identifier
Reset
Attr.
Function / Description
31dt0 EXT_EVENT_2_VALUE
00000000h rh w External Event 2 Value
Register:
GATE_TRIG_CONTROL_REG
Address:
C0h
Bits:
31dt0
Reset value:
00000000h
Attributes: (r) (w)
Description:
Timer Gate Control Register
Bit
Identifier
Reset
Attr.
Function / Description
0
TIM_0_INT_GATE_TRIG
0h
r w
Software Gate-/Trigger signal Timer
0
1
TIM_1_INT_GATE_TRIG
0h
r w Software Gate-/Trigger signal Timer