Copyright © Siemens AG 2016. All rights reserved
388
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
1: Reads LOC_IO31 Out
Register:
LOCAL_OUT_READ_H
Address: 4Ch
Bits:
31dt0
Reset value: 0h
Attribu-
tes:
r
w
Description:
Selection of GPIO_In path
Bit Identifier
Reset Attr. Function / Description
0 GPIO64_IN_MUX
xh
r w
0: Reads GPIO64 pad
1: Reads LOC_IO32 Out
1 GPIO65_IN_MUX
xh
r w
0: Reads GPIO65 pad
1: Reads LOC_IO33 Out
2 GPIO66_IN_MUX
xh
r w
0: Reads GPIO66 pad
1: Reads LOC_IO34 Out
3 GPIO67_IN_MUX
xh
r w
0: Reads GPIO67 pad
1: Reads LOC_IO35 Out
4 GPIO68_IN_MUX
xh
r w
0: Reads GPIO68 pad
1: Reads LOC_IO36 Out
5 GPIO69_IN_MUX
xh
r w
0: Reads GPIO69 pad
1: Reads LOC_IO71 Out
6 GPIO70_IN_MUX
xh
r w
0: Reads GPIO70 pad
1: Reads LOC_IO38 Out
7 GPIO71_IN_MUX
xh
r w
0: Reads GPIO71 pad
1: Reads LOC_IO39 Out
8 GPIO72_IN_MUX
xh
r w
0: Reads GPIO72 pad
1: Reads LOC_IO40 Out
9 GPIO73_IN_MUX
xh
r w
0: Reads GPIO73 pad
1: Reads LOC_IO41 Out
10 GPIO74_IN_MUX
xh
r w
0: Reads GPIO74 pad
1: Reads LOC_IO42 Out
11 GPIO75_IN_MUX
xh
r w
0: Reads GPIO75 pad
1: Reads LOC_IO43 Out
12 GPIO76_IN_MUX
xh
r w
0: Reads GPIO76 pad
1: Reads LOC_IO44 Out
13 GPIO77_IN_MUX
xh
r w
0: Reads GPIO77 pad
1: Reads LOC_IO45 Out
14 GPIO78_IN_MUX
xh
r w
0: Reads GPIO78 pad
1: Reads LOC_IO46 Out
15 GPIO79_IN_MUX
xh
r w 0: Reads GPIO79 pad