Copyright © Siemens AG 2016. All rights reserved
391
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
11 D_CACHE_PAR
xh
r
h
w
A parity error has occurred in the D-
cache during reading
12 I_TAG_PAR
xh
r
h
w
A parity error has occurred in the I-
Tag RAM during reading
13 D_TAG_PAR
xh
r
h
w
A parity error has occurred in the D-
Tag RAM during reading
14
xh
r
h
w
15
xh
r
h
w
16
xh
r
h
w
17
xh
r
h
w
Register:
EDC_INIT_DONE
Address: 58h
Bits:
31dt0
Reset value: 0h
Attribu-
tes:
rh
Description:
EDC Init Done register - the status can be read
Bit Identifier
Reset Attr. Function / Description
0 I_TCM926_INIT_DONE
xh
r
h
1: Initialization of the EDC bits in the
I-TCM of ARM926 is complete
1 D_TCM926_INIT_DONE
xh
r
h
1: Initialization of the EDC bits in the
D-TCM of ARM926 is complete
2 GDMA_INIT_DONE
xh
r
h
1: Initialization of the EDC bits in the
GDMA is complete
3 PN_IP_INIT_DONE
xh
r
h
1: Initialization of the EDC bits in the
PN_IP is complete
4 PERIF_INIT_DONE
xh
r
h
1: Initialization of the EDC bits in
PER-IF is complete
5
xh
r
h
6
xh
r
h
Register:
TCM926_MAP
Address: 5Ch
Bits:
31dt0
Reset value: 0h
Attribu-
tes:
r
w