Copyright © Siemens AG 2016. All rights reserved
412
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
Register:
SPI_PARITY_ERROR
Address: B0h
Bits:
31dt0
Reset value: 0h
Attribu-
tes:
rh
w
Description:
SPI1/2 parity error (there is only a parity check when SPI
data are read in the address range with APB address
bits(10dt9) = 01)
Bit Identifier
Reset Attr. Function / Description
0 SPI1_PARITY_ERR
0h
r
h
w 1: Parity-Error SPI1 (Even Parity)
1 SPI2_PARITY_ERR
0h
r
h
w 1: Parity-Error SPI2 (Even Parity)
Register:
XHIF_MODE
Address: B8h
Bits:
31dt0
Reset value: 0h
Attribu-
tes:
r
w
Description:
Umschalten XHIF-Pin zwischen XHIF_A20 und
XHIF_XCS_R
Bit Identifier
Reset Attr. Function / Description
0 XHIF_MODE
0h
r w
The input pin XHIF_XCS_R_A20 is
used as
0: Page register chip select
(XHIF_XCS_R)
1: Address line (XHIF_A20)
(The XHIF input not used is switched
to inactive, i.e. XHIF_A20='0',
XHIF_XCS_R='1')
Register:
EXT_DRIVER_EN
Address: BCh
Bits:
31dt0
Reset value: 0h
Attribu-
tes:
r(h)
w
Description:
Bit Identifier
Reset Attr. Function / Description
0 CS0_ENABLE
0h
r
h
w
1: CS0 activates XOE_DRIVER
0: CS0 has no effect on
XOE_DRIVER
When the reset is cleared, the invert-
ed value of XRDY_BF is latched.