Copyright © Siemens AG 2016. All rights reserved
70
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
2.3.2.16 Address Mapping
Start_Address
End_Address
Modul/Memory_Name
Interface
4000h
4AFFFh
icu_ertec_addr_dec_top AHB
4000h
7FFFh
icu96_inst
AHB
8000h
BFFFh
icu8_inst
AHB
48000h
4AFFFh
icu_general_registers_inst AHB
Module
Register/Memory
Read
Write
Address
/icu_ertec_addr_dec_top/icu96_inst
ID_REGISTER
r
4000h
IRVEC
rh
4004h
ACK
rht
4008h
IRCLVEC
wt
400Ch
MASKALL
r
w
4010h
EOI
t
4014h
UNLOCK_RD_ONLY_ACK
r
w
4018h
MASK_ALL_INPUT_EN
r
w
401Ch
LOCKREG
r
w
4020h
MASKREG0
r
w
5000h
MASKREG1
r
w
5004h
MASKREG2
r
w
5008h
IRR0
rh
5100h
IRR1
rh
5104h
IRR2
rh
5108h
ISR0
rh
5200h
ISR1
rh
5204h
ISR2
rh
5208h
TRIGREG0
r
w
5300h
TRIGREG1
r
w
5304h
TRIGREG2
r
w
5308h
EDGEREG0
r
w
5400h
EDGEREG1
r
w
5404h