Copyright © Siemens AG 2016. All rights reserved
78
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
Register:
MASKREG0
Address:
5000h
Bits:
31dt0
Reset value:
FFFFFFFFh
Attributes:
r
w
Description:
Interrupt Mask Register
Enable/disable the interrupt inputs
0 – 31 inputs of the interrupt controller
0' = Interrupt input enabled
'1' = Interrupt input disabled
Register:
MASKREG1
Address:
5004h
Bits:
31dt0
Reset value:
FFFFFFFFh
Attributes:
r
w
Description:
Interrupt Mask Register
Enable/disable the interrupt inputs
32 – 63 inputs of the interrupt controller
0' = Interrupt input enabled
'1' = Interrupt input disabled
Register:
MASKREG2
Address:
5008h
Bits:
31dt0
Reset value:
FFFFFFFFh
Attributes:
r
w
Description:
Interrupt Mask Register
Enable/disable the interrupt inputs
64 – 95 inputs of the interrupt controller
0' = Interrupt input enabled
'1' = Interrupt input disabled
Register:
IRR0
Address:
5100h
Bits:
31dt0
Reset value:
00000000h
Attributes:
rh
Description:
Request Register
Flag for the Interrupt Request detected as result of a positive edge
0 – 31 inputs of the interrupt controller
'0' = No request
'1' = Request has occurred
Register:
IRR1
Address:
5104h
Bits:
31dt0
Reset value:
00000000h
Attributes:
rh
Description:
Request Register
Flag for the Interrupt Request detected as result of a positive edge
32 – 63 inputs of the interrupt controller
'0' = No request
'1' = Request has occurred