2.3.4.2.1.1
HW Trigger with HW_JOB_START Input Signals (Edge-Sensitive)
One of the 64 possible HW_JOB_START trigger inputs can be selected in each
GDMA_JOB_CTL
register with the HW_SELECT bit field. This means that there is
no
fixed assignment of JOB trigger signals (HW_JOBx_START) to JOB-CTL register number
(GDMA_JOBx_CTL register).
The typical applications are free-running time triggers (cyclic pulse upon zero run) that
trigger cyclic DMA transfers. The
HW_FLOW_EN
bit in the
GDMA_JOBx_CTL
register
must be set to 0.
Port
Source
Acti-
ve
level
Description
HW_JOB_START
(starts the job in HW by rising edge):
HW_JOB_START_0
PNPLL_OUT11 (PN-IP)
high
coming from PNPLL in PN-IP
HW_JOB_START_1
PNPLL_OUT12 (PN-IP)
high
coming from PNPLL in PN-IP
HW_JOB_START_2
PNPLL_OUT13 (PN-IP)
high
coming from PNPLL in PN-IP
HW_JOB_START_3
PNPLL_OUT14 (PN-IP)
high
coming from PNPLL in PN-IP
HW_JOB_START_4
PNPLL_OUT15 (PN-IP)
high
coming from PNPLL in PN-IP
HW_JOB_START_5
PNPLL_OUT16 (PN-IP)
high
coming from PNPLL in PN-IP
HW_JOB_START_6
PNPLL_OUT17 (PN-IP)
high
coming from PNPLL in PN-IP
HW_JOB_START_7
PNPLL_OUT18 (PN-IP)
high
coming from PNPLL in PN-IP
HW_JOB_START_8
PNPLL_OUT19 (PN-IP)
high
coming from PNPLL in PN-IP
HW_JOB_START_9
PNPLL_OUT20 (PN-IP)
high
coming from PNPLL in PN-IP
HW_JOB_START_1
0
TIM_OUT0 (Timer Unit)
high
coming from Timer 0 in the Timer Unit
HW_JOB_START_1
1
TIM_OUT1 (Timer Unit)
high
coming from Timer 1 in the Timer Unit
HW_JOB_START_1
2
TIM_OUT2 (Timer Unit)
high
coming from Timer2 in the Timer Unit
HW_JOB_START_1
3
TIM_OUT3 (Timer Unit)
high
coming from Timer 3 in the Timer Unit
HW_JOB_START_1
4
TIM_OUT4 (Timer Unit)
high
coming from Timer 4 in the Timer Unit
HW_JOB_START_1
5
TIM_OUT5 (Timer Unit)
high
coming from Timer 5 in the Timer Unit
HW_JOB_START_1
6
Reserved
HW_JOB_START_1
7
Reserved
HW_JOB_START_1
8
Reserved
HW_JOB_START_1
9
Reserved
HW_JOB_START_
20...63
Not used for ERTEC
200P;
tied to inactive values
Table 11: DMA, Table of HW_JOB_START_Signals