10 Memory Description
This section presents a detailed description of the memory areas of all integrated function groups.
10.1 Memory Partitioning of the ERTEC 200
The table below lists the AHB masters along with their options for accessing various memory areas.
Start- and
Endadress
Seg.
Function Area for
ARM9
Function Area for
IRTE
Function Area for
LBU
Function Area for
DMA
0000 0000
0FFF FFFF
0
Boot ROM(0-8kB)
EMIF-SDRAM
(0-128MB)
EMIF-Memory
(0-64MB)
D-TCM(4kB)
locked I-Cache
(2/4/6kB)
Boot ROM(0-8kB)
EMIF-SDRAM
(0-128MB)
EMIF-Memory
(0-64MB)
Boot ROM(0-8kB)
EMIF-SDRAM
(0-128MB)
EMIF-Memory
(0-64MB)
Boot ROM(0-8kB)
EMIF-SDRAM
(0-128MB)
EMIF-Memory
(0-64MB)
1000 0000
1FFF FFFF
1
IRT-Switch-
Controller
IRT-Switch-
Controller
IRT-Switch-
Controller
Not used
2000 0000
2FFF FFFF
2
EMIF (SDRAM)
EMIF (SDRAM)
EMIF (SDRAM)
EMIF (SDRAM)
3000 0000
3FFF FFFF
3
EMIF
( Area: Bank 0-3)
EMIF
( Area: Bank 0-3)
EMIF
( Area: Bank 0-3)
EMIF
( Area: Bank 0-3)
4000 0000
4FFF FFFF
4
all APB interfaces
incl. Boot-ROM
Not used
all APB interfaces
incl. Boot-ROM
all APB interfaces
incl. Boot-ROM
5000 0000
5FFF FFFF
5
ARM-ICU
Not used
Not used
Not used
6000 0000
6FFF FFFF
6
Not used
Not used
Not used
Not used
7000 0000
7FFF FFFF
7 EMIF-Register
Not
used
EMIF-Register Not
used
8000 0000
8FFF FFFF
8
DMA
Not used
Not used
Not used
9000 0000
FFFF FFFF
9 - 15
Not used
Not used
Not used
Not used
Table 33: Partitioning of Memory Areas
The D-TCM with a maximum size of 4 Kbytes can be displayed on any aligned address area. The ARM946E-S then
accesses the D-TCM under this address and not the AHB bus. In addition, the locked I-cache of 2/4/6 Kbytes can be
displayed on any aligned address area.
Only the ARM946E-S can access both address areas.
IRT accesses to its own KRAM do not use the AHB bus. These accesses are implemented in the IRT switch controller.
The KRAM can be addressed starting from the memory area 0x1010_0000. An access in the non-permissible register
area is detected by an IRT-internal error signal and not by an AHB acknowledgement time-out error.
Copyright © Siemens AG 2007. All rights reserved.
91
ERTEC 200 Manual
Technical data subject to change