44
FLUDEX 4612 en
Operating instructions 10/2017
10.
Maintenance and repair
Observe the information in section 3, "Safety instructions"!
DANGER
Danger to life through switchedon installation
Risk of being caught or drawn in by rotating and/or movable parts.
To carry out work on the coupling, the system must always be stopped. The drive unit must be secured
against being switched on accidentally (e.g. by locking the key switch or removing the fuses from the
power supply).
A notice should be attached to the ON switch stating clearly that work on the coupling is in progress. The
relevant accident prevention regulations at the place of installation apply as well.
At the same time the complete installation must be without load, so that no danger occurs during
demounting operations.
WARNING
Serious injury
Rotating components may cause injury during work on the still rotating coupling.
All work on the coupling must be carried out only when it is at a standstill. Secure the drive unit to prevent
unintentional switchon. A notice should be attached to the ON switch stating clearly that work on the
coupling is in progress. The relevant accident prevention regulations at the place of installation apply as
well.
CAUTION
Risk of corrosion burns through chemical substances
Avoid burns when working with corrosive cleaning agents.
Observe manufacturer’s instructions for handling cleaning agents and solvents.
Wear suitable personal protective equipment (gloves, safety glasses).
Note
During fitting work comply with the relevant safety and environmental regulations.
Sufficient room and tidiness and cleanliness must be ensured during fitting work.
WARNING
Risk of scalding
Risk of scalding immediately after switching off.
Never change the operating fluid immediately after operation.
Allow the coupling and operating fluid to cool down.