15
FLUDEX 4612 en
Operating instructions 10/2017
4.3
Storage of the coupling
NOTICE
Risk of damage to the coupling through improper storage
Impairment of the physical properties of the coupling and/or coupling parts.
The storage area must be dry (air humidity less than 65 %) and free from dust. Ensure that no
condensation occurs. Do not store with aggressive chemicals, acids, alkalis, etc.
If the coupling contains elastomer components, no ozonegenerating equipment of any kind, such as
fluorescent light sources, mercury vapour lamps or hightension electrical equipment, must be allowed
into the storage areas.
Storage of the coupling on suitable aids or in suitable containers.
Note
The coupling is delivered in a preserved condition and can be stored in a covered, dry place and free from
dust for up to 3 months. If the unit is to be stored for a longer period, it should be treated with a longterm
preservative agent (Flender must be consulted).
NOTICE
Damage to the coupling through damage to the flexible elements
Before cleaning the coupling parts and applying the longterm preservative agent, the flexible
elements (12) in figure 3 must be removed.
The shaftsealing rings must not come into contact with solvents.
Correctly stored couplings retain their properties unchanged for up to five years. Improper treatment of the
flexible elements and/or seals will negatively affect their physical properties. Such negative effects may
be caused by e.g. the action of oxygen, ozone, extreme temperatures, light, moisture, or solvents.
NOTICE
Risk of damage to the coupling through improper storage
Damage to the coupling through freezing of operating fluid.
In case of types provided for operation with water, the water or water emulsion must be drained off before
storing at temperatures below 0 °C.
Frost hazard.
4.4
Storage area for a protracted period
The storage area must be dry and free from dust. The couplings must not be stored with chemicals,
solvents, motor fuels, acids, etc. Furthermore, the flexible elements and seals should be protected against
light, in particular direct sunlight and bright artificial light with a high ultraviolet content.
NOTICE
Risk of damage to the coupling through improper storage
In case of types provided for operation with water, the water must be drained off before storing at
temperatures below 0 °C.
Frost hazard.