8
FLUDEX 4612 en
Operating instructions 10/2017
1.
Technical data
Enclosed with the coupling delivery and the documentation is an orderspecific dimensioned drawing
showing all the technical data necessary for fitting (see Fitting data field). The coupling can be fitted with
the aid of these instructions
only in
conjunction with the orderspecific drawing of the coupling
.
The technical data to the FLUDEX couplings listed in these instructions are documented on the
orderspecific drawing of the coupling
(see "Operating and Coupling Data" fields) and in the current
product catalogue and are available on request or can be accessed at any time on the Internet (see cover
at back).
Because of customerspecific adaptations the standard design is frequently deviated from. The
technical
data on the
orderspecific drawings of the couplings should always be followed before
the data
in the current product catalogue, therefore.
These data together with the contractual agreements on the coupling determine the limits of its proper use.
1.1
General data
This manual applies only to FLUDEX couplings in the
"FNO", "FNA", "FND", "FNDB"
and
"FNDS"
series, which are designed for operation with water or with a water emulsion.
DANGER
Risk of explosion
Risk of explosion when using unsuitable components in potentially explosive areas.
Use the coupling only for the approved zones and equipment groups. In case of doubt, contact Flender.
DANGER
Risk of explosion
Risk of explosion in case of inadequate design and combination of the brake disk and/or brake drum in
potentially explosive areas.
Use the brake disk and brake drum only for the approved zones and equipment groups.
Dió not exceed the ignition temperature.
The brake disk and/or brake drum must be design in a way to prevent exceeding the guaranteed
maximum surface temperature with maximum energy input.
Prevent mechanical sparks which may create ignition.
WARNING
Risk of serious injury through flying fragments
Risk of serious injury through flying fragments and/or risk of damage to the coupling.
In the event of a change in operating conditions (output, speed, prime mover and driven machine)
the design must always be checked.
WARNING
Serious injury
Risk of serious injury through falling components or quenching.
Damage to coupling parts when using unsuitable transport equipment.
When handling these products, use only lifting and handling equipment of sufficient loadbearing
capacity.
Transport of the coupling must be carried out so as to avoid personal damage and damage to the
coupling.
Summary of Contents for FLENDER FLUDEX FNA