Siemens Home and Office Communication Devices GmbH & Co. KG
Confidential
8
SHC CC RCT
Version 1.5
J. Junggebauer
4 Test setup recommendation
- Gigaset 4170 or 4175 to be used as a PBX
- Gigaset handset which is registered on Gigaset 4175
- Gigaset A160, A260, A165 or A265 base station to test customer‘s
Handset
- Gigaset A16 and A26 handset to test customer‘s base station
- 2 multimeters:
- 1 voltmeter to measure the PSTN line voltage of the customer‘s base
- 1 amperemeter to measure the AC-current of the AC-adaptor connected
to the customers base station
- 2 modified cables:
- 1 AC adaptor where the cable is opened (cut off) for the amperemeter
- 1 Mini-Western PSTN cable with a parallel cable for the voltmeter
See next page for the setup (picture shows C450 instead of A160).