18
Preparing the mobile unit
Mobile unit operating hours (battery life):
These times are only achieved after several charging and
discharging cycles!
Permitted batteries:
Type
Standby mode
(hours)
When phone in use
(hours)
NiCd, 700 mAh
up to 100
up to 10
NiMH, 1100 mAh
up to 160
up to 15
NiMH, 1500 mAh
up to 220
up to 20
Nickel-Cadmium (NiCd)
Nickel-Metal-Hydride (NiMH)
Sanyo N-3U (700 mAh)
Sanyo H-3 U (1500 mAh)
GP GP60AAKC (600 mAh)
GP GP130 AA HC (1300 mAh)
Varta 751RS (700 mAh)
GP GP150 AA HC (1500 mAh)
Varta VH 1101 (1100 mAh)
Panasonic HHR-110 AA (1100 mAh)
Friwo NiMH (1400 mAh)
Toshiba TH-1200 AARE (1200 mAh)
Instructions for the use of NiMH batteries:
After you have inserted the NiMH batteries, we recom-
mend that the mobile unit be fully charged and then dis-
charged until the battery low beep is heard, i.e. without
replacing the batteries in the charging shell. This ensures
that the charge status display
ý7
of the mobile unit is
adapted to the increased operating life of the NiMH bat-
teries.
You can subsequently place your mobile unit in the charg-
ing shell each time it is used. Charging is electronically
controlled which ensures that the batteries are charged
optimally.