background image

Configuration for gatekeeper mode

Startup

For internal use only

 

A31003-K5020-S100-4-7620

3-8

Service Manual

lan2de.c03

Configuring services

Configuring neighbors

Note

Detailed configuration examples can be found in the Administration Manual for HiPath 
HG 1500 (A31003-K5020-B811-*-7619).

Step

Task

1.

Press the Services button and then click Add.

2.

Under Description, enter a description for the service, e.g. “Hicom 150 E”.

3.

Under Prefix, enter the correct code, which must match the gateway prefix 
set up in the HLB2, e.g. “0” (only digits, possibly more than one).

4.

Enable Allow as default for online endpoints if the service is to be as-
signed to all endpoints registered at the gateway (otherwise, the service 
will need to be individually assigned to each endpoint that may use it).

5.

Enable Allow for public endpoints from other zones if endpoints from 
other H.323 zones may use the service.

Step

Task

1.

Press the Neighbors button and then click Add.

2.

Under Description, enter a description for the other zone, e.g. 
“Department XYZ”.

3.

Under IP address, enter the IP address of the gatekeeper for the other 
zone.

Summary of Contents for HiPath HG 1500

Page 1: ...Hicom 150 H Service Manual HiPath HG 1500 V 1 0 A31003 K5020 S100 4 7620 ...

Page 2: ...d in the Federal Republic of Germany Siemens Aktiengesellschaft Issued by the Information and Communication Networks Group Hofmannstrasse 51 D 81359 Munich Siemens AG 2000 All rights reserved Subject to availability Right of modfication reserved ...

Page 3: ...1 2 3 4 5 A31003 K5020 S100 4 7620 Hicom 150 H HiPath HG 1500 V 1 0 Service Manual Additional information Administration Startup Installation Introduction ...

Page 4: ...icePoint Com Pro 2 1 2 1 1 HXGS 2 1 2 1 2 HXGM 2 4 2 1 3 V 24 interface 2 7 2 1 4 Interfaces to the LAN 2 7 2 2 Part numbers 2 8 2 3 HiPath HG 1500 installation 2 9 2 3 1 Installation requirements 2 9 2 3 2 Slot 2 9 2 3 3 Installation procedure 2 10 3 Startup 3 1 3 1 Initial startup of HiPath HG 1500 3 1 3 1 1 Initial startup via a LAN port 3 1 3 1 2 Initial startup via the serial interface 3 2 3 ...

Page 5: ...03 K5020 S100 4 7620 0 2 Service Manual lan2detoc fm 5 Additional information 5 1 5 1 Integrating various network topologies 5 1 5 1 1 Star topology with hub 10 100 BaseT 5 1 5 1 2 Bus topology 10 Base2 5 1 5 2 Updating SW 5 3 Index Z 1 ...

Page 6: ... For internal use only Figures Figures 0 Figure 2 1 HXGS interfaces S30810 Q2931 X X100 2 2 Figure 2 2 HXGM interfaces S30810 Q2930 X X100 2 5 Figure 3 1 Installation for gatekeeper mode 3 6 Figure 5 1 10 100 BaseT cabling 5 1 Figure 5 2 10 Base2 cabling 5 2 ...

Page 7: ...Figures For internal use only A31003 K5020 S100 4 7620 0 4 Service Manual lan2delof fm ...

Page 8: ...GS application option slot 2 1 Table 2 2 HXGS hardware variants 2 1 Table 2 3 10 100 BaseT interface contact assignment 2 3 Table 2 4 HXGM application option slot 2 4 Table 2 5 HXGM hardware variants 2 4 Table 2 6 HXGM LED concept 2 6 Table 2 7 10 100 BaseT interface contact assignment 2 6 Table 2 8 Slots 2 9 Table 2 9 Installation procedure for OfficePoint Com 2 10 ...

Page 9: ...Tables For internal use only A31003 K5020 S100 4 7620 0 6 Service Manual lan2delot fm ...

Page 10: ...is suitable for Hicom 150 E Office as of Version 2 2 or Hicom 150 H OfficePoint OfficeCom Of ficePro models The following implementation scenarios are possible Voice gateway between LAN H 323 and standard telephones e g Netmeet ing Telephoning from the PC voice over IP with Optiset features available at the PC or via the Xpress client WAN connections via the ISDN network including PPP Multilink Re...

Page 11: ...fice Hicom 150 H Point Com Pro It is used to connect a local LAN to Hicom 150 E Office Hicom 150 H Point Com Pro systems and to link external LANs via the system s ISDN interface Telematics and CTI functions are also supported The connection to the local LAN is set up via an Ethernet twisted pair interface RJ45 connector see Figure 2 1 and Figure 2 2 In the case of OfficePoint and Com the connecti...

Page 12: ...is provided for entering and modifying data e g the IP address of the customer LAN or ISDN numbers assigned to a communication partner The data is permanently stored in HiPath HG 1500 HiPath HG 1500 Assistant also facilitates the storage of a corresponding configuration file This can then be retrieved if a board needs replacing The tool also provides a facility for querying the software version Ac...

Page 13: ...ssword concept Further information is contained in the Hicom 150 H Rel 2 0 2 2 Service Manual Table 1 1 Starting Hicom system administration Service Step Input Explanation 1 95 Start system administration 2 31994 User 31994 default 3 31994 Password 31994 default or 1 Change user and or password 2 Confirm user and or password ...

Page 14: ...red in Hicom 150 E Office Hicom 150 H Point Com Pro for call numbers used by HiPath HG 1500 Hicom toll restriction for outgoing seizure is per formed based on this trunk access in the same way as for outgoing calls 1 5 3 Gatekeeper The following functions are performed by a gatekeeper in an H 323 network Registering H 323 end units Managing rights and services Converting station numbers to logical...

Page 15: ...nference units are being used IP telephony can also be implemented in H 323 networks without gatekeepers Note however that the connection can only be set up via the IP address in this case so no authorizations and bandwidth control are possible In general the following applies without gatekeepers many features may be disabled or subject to severe restrictions ...

Page 16: ...0 Board slot Table 2 1 HXGS application option slot Possible application Boards Slot OfficePoint Hicom 150 E Office as of V 2 2 P30370 P722 A680 G1 1 All slots OfficeCom Old HW CBFC Hicom 150 E Office as of V 2 2 P30370 P723 A680 G1 2 Slot 4 and 5 only OfficeCom New HW CBPC Hicom 150 E Office as of V 2 2 P30370 P721 A680 G1 2 All slots 2 boards may be operated in parallel OfficeCom old HW CBFC S30...

Page 17: ... interface X1 50 pin to the system X2 6 pin shielded MiniDin socket for V 24 interface see Section 2 1 3 The following connection option is provided for connection to a LAN X3 8 pin Western socket for LAN 10 100 Base T RJ45 socket twisted pair A twisted pair cable is used as the transmission medium for 10 100 Base T The cable is connected to the HiPath HG 1500 board HXGS OfficeCom and OfficePoint ...

Page 18: ...l use only Installation Note Direct Ethernet twisted pair connection to HiPath HG 1500 The RJ45 cable must be crossed as follows Table 2 3 10 100 BaseT interface contact assignment X3 8 pin Western socket Function 1 Transmit wire 2 Transmit wire 3 Receive wire 6 Receive wire 4 5 7 8 not used 1 3 2 6 3 1 6 2 ...

Page 19: ...ath HG 1500 HXGM Voice and Data S30810 Q2930 X HiPath HG 1500 HXGM Data only S30810 Q2930 X100 Board slot Table 2 4 HXGM application option slot Possible application Boards Slot OfficePro Hicom 150 E Office as of V 2 2 P30370 P720 A580 G1 3 All slots except 2 Several boards may be operated in parallel Table 2 5 HXGM hardware variants System type Services DSPs Board ID OfficePro Data only 0 HXGM Of...

Page 20: ...Din socket for V 24 cable see Section 2 1 3 The board is connected to the system via the backplane An adapter for the back plane part number C39228 A7195 A10 is used to connect the LAN with an RJ45 connector Figure 2 2 HXGM interfaces S30810 Q2930 X X100 HXGM to BP V 24 X2 RJ45 adapter cable connection to LAN Backplane not used LAN X39 X49 X59 X69 X79 LED H2 green LED H1 red ...

Page 21: ...ard therefore V 24 charge mode On Off Board is included in Firmware e g following reset re boot On Off Off Board at SW start reboot Off Off On Board in idle status following reboot call number of logon router Off On At least one B channel occupied On On Approx 20 s long Board ready to activate reset e g fol lowing APS transfer or a FATAL error waiting for Hicom reset Table 2 7 10 100 BaseT interfa...

Page 22: ... A SLIP connection is required for Assistant administration of HiPath HG 1500 How ever a SLIP connection is not possible for the Loader 2 1 4 Interfaces to the LAN The physical configuration of the LAN interface is predefined by the IEEE 802 standard The interface conforms to international standards for electrical safety and electromagnetic compatibility EMC The electrically isolated coupling of t...

Page 23: ...30300 P1509 CSTA converter P30300 P1530 A1 P30300 P1530 A1 P30300 P1530 A1 VCAPI SW P30300 P1561 A1 P30300 P1561 A1 P30300 P1561 A1 CTI TAPI 1P 4 clients P30152 P1091 A1 P30152 P1091 A1 P30152 P1091 A1 CTI TAPI 3P V2 30 users F50035 E302 X11 F50035 E302 X11 F50035 E302 X11 CTI TAPI 3P V2 80 users F50035 E302 X12 F50035 E302 X12 F50035 E302 X12 CTI TAPI 3P V2 250 users F50035 E302 X13 F50035 E302 X...

Page 24: ... Table 2 4 2 3 2 Slot Special country variants are not provided for Examples of maximum system configurations Table 2 8 Slots Maximum system configurations for Hicom 150 E OfficePro are contained in the Hicom 150 E Office Service Manual System Slot Configuration Trunk Station OfficePoint 2 SLA 4 8 16 SLU8 STLS 2 4 TLA 2 4 8 HiPath HG 1500 16 ports ISDN So MSI lines 8 Upo E 16 from OfficeCom 6 SLA ...

Page 25: ... procedure Table 2 9 Installation procedure for OfficePoint Com This sequence must be observed in order to guarantee successful LAN board login In the case of the Hicom 150 E OfficePro the board can be plugged and unplugged without disconnecting the power supply Step Task 1 Remove the power plug 2 Insert the board 3 Insert the power plug ...

Page 26: ... port Prerequisites The network card with the TCP IP protocol must function correctly The HiPath HG 1500 Assistant must be installed on the PC Step Task 1 Configure the IP address of the PC 10 144 233 64 in the network environment 2 Configure the gateway 10 144 233 63 3 From the DOS command window ping the HiPath HG 1500 IP 10 144 233 63 4 Generate an empty customer database and load to HiPath HG ...

Page 27: ...ible via a LAN port Prerequisite The SLIP connection in the dial up network must be installed in accordance with the operating system Step Task 1 Connect the serial interface cable S30122 X5468 X 2 Install Assistant HiPath HG 1500 3 Configure the IP address 1 0 0 2 of the PC SLIP 4 From the DOS command window ping the HiPath HG 1500 IP 10 144 233 63 5 Generate an empty customer database and load t...

Page 28: ...odems activate Don t detect my modem I will select it from a list Click Next Standard Modem Types Standard 9600 bps Modem Next Select COM port 4 Configure Dial Up Networking Connection to Hicom 150 E Office My Computer Dial Up Networking Create New Connection Select Standard 9600 bps Modem Next select a Com port connection to Hicom 150 E Office and specify the name of the connection e g SLIP to HL...

Page 29: ...t my modem I will select it from a list Click Next Standard Modem Types Standard 9600 bps Modem Next Select COM port 3 Configure Dial Up Networking Connection to Hicom 150 E Office My Computer Dial Up Network Create New Connection Select Standard 9600 bps Modem Then select the COM port connection to Hicom 150 E Office and specify the name of the connection e g SLIP to HLB The modem is normally cor...

Page 30: ...eted My Computer Control Panel Under Add Modems activate Don t detect my modem I will select it from a list Click on Next Standard Modem Types Standard 9600 bps Modem Next select a Com port 3 Configure Dial Up Networking Connection to Hicom 150 E Office My Computer Dial Up Networking Telephone Book Entry e g SLIP Hi com Continue Continue Continue Call No e g 1 Continue and press Finish Continue En...

Page 31: ...red at the gatekeeper H 323 standard clients such as Netmeeting 3 01 HiNet LP5100 HiNet TA1100 etc Note In order to reach a port station line of group 1 all stations of group 2 must dial an additional code This code is stripped for traffic in the direction to the HICOM by Hi Path HG 1500 HLB2 and inserted for traffic in the reverse direction i e stations of group 1 do not dial the code The code mu...

Page 32: ...s Configure the clients with a gatekeeper connection using IP address 255 255 255 255 Clients without a gatekeeper connection must be configured with the fixed IP address of the corresponding PC 3 Under Voice Clients Xpress Clients There are no additional aspects to be noted here Step Task 1 Capacity Characteristics Set the IRQ interval to 0 if the registered endpoints do not need to be cy clicall...

Page 33: ...ect code which must match the gateway prefix set up in the HLB2 e g 0 only digits possibly more than one 4 Enable Allow as default for online endpoints if the service is to be as signed to all endpoints registered at the gateway otherwise the service will need to be individually assigned to each endpoint that may use it 5 Enable Allow for public endpoints from other zones if endpoints from other H...

Page 34: ...rrors i e the development trace customer trace and errored memory If system crashes have occurred with the board make sure that you also produce a stack dump and submit it together with the traces to the responsible Development department The traces and the stack dump can withstand a reset but are lost in the event of a power failure 4 2 Determining the firmware version of the board The firmware v...

Page 35: ...Determining the firmware version of the board Administration For internal use only A31003 K5020 S100 4 7620 4 2 Service Manual lan2de c04 ...

Page 36: ...T Ethernet A standard hub emulates a bus internally If a cable malfunctions only one terminal is affected The integrated HiPath HG 1500 can be connected directly For more information on connector assignment see Table 2 3 and Table 2 7 Figure 5 1 10 100 BaseT cabling Notes 10 100 MBit s Autosense Max total length from HUB switch to PC 100 m incl PATCH cable 5 1 2 Bus topology 10 Base2 The tradition...

Page 37: ...ing capacity of the network structured star cabling is becoming increasingly popular The integrated HiPath HG 1500 can only be connected via a hub or switch Figure 5 2 10 Base2 cabling Note The coaxial cable must have terminating resistors at both ends No spur lines are permitted in the coaxial cable The T units must be positioned directly on the terminals Max length of the LAN is 185 m Hicom 150 ...

Page 38: ...dating SW lan2de c05 A31003 K5020 S100 4 7620 Service Manual 5 3 For internal use only Additional information 5 2 Updating SW Upgrading from HiPath HG 1500 Rel 1 0 to Rel 1 1 is performed via APS transfer ...

Page 39: ...Updating SW Additional information For internal use only A31003 K5020 S100 4 7620 5 4 Service Manual lan2de c05 ...

Page 40: ...tion CTRL Control DC Direct current DFÜ German abbreviation for Dial Up Networking DSP Digital Signal Processor DSS1 Digital Subscriber Signaling System One D channel protocol EMC Electromagnetic Compatibility FW Firmware GK Gatekeeper GSM Global System for Mobile Communication H 323 ITU standard for voice over LAN HFA Hicom Feature Access HLB2 HiPath HG 1500 Rel 1 1 HXGM HXGS HXGM Hicom Xpress Ga...

Page 41: ... PING Packet Internet Groper PPP Point to Point Protocol RAS Remote Access Service SIC Serial Interface Cable SLA Subscriber Line Analog Hicom board SLIP Serial Line Interface Protocol SLU Subscriber Line UP0 E Hicom board SNMP Simple Network Management Protocol STLS Subscriber Trunk Line S0 Hicom board TAPI Telephony Application Programming Interface TCP Transmission Control Protocol TLA Trunk Li...

Page 42: ...G 1500 Functional environment 1 5 Parallel operation 1 5 HG 1500 Assistant 1 3 HG 1500 installation 2 9 Hicom password concept 1 4 HXGM 2 4 HXGM application option slot 2 4 HXGM hardware variants 2 4 HXGM interfaces S30810 Q2930 X X100 2 5 HXGM LED concept 2 6 HXGS 2 1 HXGS application option slot 2 1 HXGS hardware variants 2 1 I Initial startup preparing a Win NT PC 3 5 preparing a Win95 PC 3 3 p...

Page 43: ... boards for Hicom OfficePoint Com Pro 2 1 Least Cost Routing LCR 1 5 P Part numbers 2 8 S Service information 1 2 Short description 1 2 Slot 2 9 Star topology with hub 10 100 BaseT 5 1 Starting Hicom system administration Service 1 4 Startup 3 1 T Toll restriction 1 5 Tracing with development trace 4 1 Trunk access 1 5 U Updating SW 5 3 V V 24 interface 2 7 ...

Reviews: