10
Nozzle values for the wok burner (optional)
Nozzle values for the high output burner (optional)
Nozzle values for the gas grill burner in the gas oven
(optional)
Nozzle values for the lower burner on the gas oven with
thermostat (optional)
*G20/G25
G20
G20
G25
G25
G30/G31
**G30 G25.1 G27
G30
Gas pressure (mbar)
20/25
20
25
20
25
28-30/37 50
25
20
37
Nozzle (mm)
1.35
1.35
1.20
1.45
1.40
0.96
0.75
1.40
1.46
0.90
Bypass nozzle (mm)
0.88
0.88
0.88
0.88
0.88
0.55
0.55
0.88
0.88
0.55
Max. input power (kW)
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
Min. input power (kW)
≤
1.7
≤
1.7
≤
1.7
≤
1.7
≤
1.7
≤
1.7
≤
1.7
≤
1.7
≤
1.7
≤
1.7
Gas flow at 15 °C and 1013 mbar m³/h 0.342/
0.398
0.342
0.342
0.398 0.398 -
-
0.398 0.418 -
Gas flow at 15 °C and 1013 mbar g/h
-
-
-
-
-
261
261
-
-
261
* For France and Belgium
** For G30 (50 mbar), nozzle set HEZ298070 must be ordered from our after-sales service.
*G20/G25
G20
G20
G25
G25
G30/G31
**G30 G25.1 G27
G30
Gas pressure (mbar)
20/25
20
25
20
25
28-30/37 50
25
20
37
Nozzle (mm)
1.16
1.16
1.10
1.34
1.21
0.85
0.75
1.21
1.38
0.80
Bypass nozzle (mm)
0.75
0.75
0.75
0.75
0.75
0.46
0.46
0.75
0.75
0.46
Max. input power (kW)
3
3
3
3
3
3
3
3
3
3
Min. input power (kW)
≤
1.3
≤
1.3
≤
1.3
≤
1.3
≤
1.3
≤
1.3
≤
1.3
≤
1.3
≤
1.3
≤
1.3
Gas flow at 15 °C and 1013 mbar m³/h 0.285/
0.332
0.285
0.285
0.332 0.332 -
-
0.332 0.348 -
Gas flow at 15 °C and 1013 mbar g/h
-
-
-
-
-
218
218
-
-
218
* For France and Belgium
** For G30 (50 mbar), nozzle set HEZ298070 must be ordered from our after-sales service.
*G20/G25
G20
G20
G25
G25
G30
**G30
G25.1
Gas pressure (mbar)
20/25
20
25
20
25
28-30
50
25
Nozzle (mm)
1.00
1.00
0.98
1.13
1.10
0.70
0.62
1.10
Bypass nozzle (mm)
-
-
-
-
-
-
-
-
Max. input power (kW)
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
Min. input power (kW)
-
-
-
-
-
-
-
-
Gas flow at 15 °C and 1013 mbar m³/h
0.2/0.233 0.2
0.2
0.233
0.233
-
-
0.233
Gas flow at 15 °C and 1013 mbar g/h
-
-
-
-
-
153
153
-
* For France and Belgium
** For G30 (50 mbar), nozzle set HEZ298070 must be ordered from our after-sales service.
*G20/G25
G20
G20
G25
G25
G30
**G30
G25.1
Gas pressure (mbar)
20/25
20
25
20
25
28-30
50
25
Nozzle (mm)
1.16
1.16
1.10
1.34
1.21
0.85
0.75
1.21
Bypass nozzle (mm)
0.76
0.76
0.67
0.80
0.70
0.48
0.45
0.70
Max. input power (kW)
3
3
3
3
3
3
3
3
Min. input power (kW)
-
-
-
-
-
-
-
-
Gas flow at 15 °C and 1013 mbar m³/h
0.285/
0.332
0.285
0.285
0.332
0.332
-
-
0.332
Gas flow at 15 °C and 1013 mbar g/h
-
-
-
-
-
218
218
-
* For France and Belgium