Instructions for connecting gas and gas conversion (for After-Sales Service only)
Measures to note ....................................................................... 2
Selecting a connection side *...........................................................2
Gas connection.......................................................................... 3
Approved connections.......................................................................3
Types of connection ...........................................................................3
Natural gas connection (NG)............................................................3
Liquid gas connection (LPG) ............................................................4
Conversion to a different gas type........................................... 4
Converting to a different gas type ...................................................4
Functional parts for the gas conversion.........................................4
Replacing the burner nozzles...........................................................5
Adjusting or replacing the burner bypass screws and setting
the small flame ....................................................................................5
Converting the appliance from natural gas to liquefied gas ......5
Conversion from liquid gas to natural gas.....................................6
Removing the control panel..............................................................6
Replacing bypass screws .................................................................7
Fitting the control panel.....................................................................7
Replacing the oven burners (optional) ...........................................7
Leak test and function test ....................................................... 8
Check the gas connection ................................................................8
Checking the burner nozzles............................................................8
Checking the bypass valves.............................................................8
Checking the oven burner nozzle (option).....................................8
Check the grill burner nozzle (option) ............................................8
Correct flame formation ............................................................ 9
Burner ...................................................................................................9
Oven ......................................................................................................9
Technical data – Gas ................................................................. 9
Measures to note
The appliance may only be converted to a different gas type
by an approved specialist, in accordance with the
instructions in this manual.
Incorrect connection and incorrect settings may cause
serious damage to the appliance. The appliance
manufacturer accepts no liability for damage and
malfunctions of this kind.
Pay close attention to the symbols indicated on the rating plate.
If there is no symbol for your country, follow the technical
guidelines that apply in your country when making settings.
Before setting up the appliance, determine the gas type and
pressure in the local supply network. Before using the
appliance for the first time, make sure that all settings have
been made correctly.
Pay attention to local and international rules and regulations.
All connection data can be found on the rating plate on the rear
of the appliance.
Enter the data in the following table:
Product number (E no.),
Manufacturing number (FD),
Enter the factory settings for gas type/gas pressure, as well as
the settings for gas type/pressure that apply after the gas
conversion, in the following table.
The changes made to the appliance and the type of connection
play an important role in ensuring that the appliance operates
correctly and safely.
Selecting a connection side *
The gas can be connected on either the right or the left. If
necessary, you can change the connection side.
Shut off the main gas supply.
If the gas is to be connected on the opposite side, the screw
fastening (size 22 key) on the gas connection that is not in use
must be fitted with a blind cap (size
24
key) and a new sealing
ring.
Once the connection side has been changed, a leak test must
be performed. See the section entitled "
Leak test
".
Note:
A torque spanner must be used when the gas is
connected.
* Option:
Only valid for some models.
E no.
FD no.
After-sales service
O
Type of gas / gas pressure
Data on the rating plate
Type of gas / gas pressure
Data after gas conversion