I-T-E Internal Accessories
37
Auxiliary Switch Identification (All With Three Leads)
AAAA
AAAA
AAAA
AAAA
AAA
AAA
AAA
AAA
AAAA
AAAA
AAAA
AAAA
A
A
A
A
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAA
AAA
AAA
AAA
Wire
Markings
Wire
Color
Switch Terminals or Contacts
C1 or C2
White
C. - Common Terminal
B1 or B2
Red
N.C. - Normally Closed Contact
(Closed when circuit breaker is tripped)
A1 or A2
Black
N.O. - Normally Open Contact (Open
when circuit breaker is tripped)
Mechanical and Electrical Check
Auxiliary and Bell Alarm Switch Kits
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
A
A
A
A
A
A
A
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAA
AAA
AAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AA
AA
AA
AAAA
AAAA
AAAA
AA
AA
AA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAA
AAA
AAA
Catalog
Number
Number of
Auxiliary
Switches
Ampere Rating of Switch
Volts AC
Volts DC
120
240
480
125
250
B00MN64
A01MN64B
A02MN64B
A01MN64
A02MN64
0
1
2
1
2
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
.5
.5
.5
.5
.5
.25
.25
.25
.25
.25
Bell Alarm Wire Identification (All With Three Leads)
AAAA
AAAA
AAAA
AAAA
AAA
AAA
AAA
AAA
AAAA
AAAA
AAAA
AAAA
A
A
A
A
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAA
AAA
AAA
AAA
Wire
Markings
Wire
Color
Switch Terminals or Contacts
C
White
C. - Common Terminal
A
Yellow
N.C. - Normally Closed Contact
(Closed when circuit breaker is tripped)
B
Brown
N.O. - Normally Open Contact (Open
when circuit breaker is tripped)
Bell Alarm Mechanical and Electrical Check
A.
Use a buzzer or light indicator attached to switch leads A
and C. With device in TRIPPED position, indicator light or
buzzer should operate.
B.
Reset breaker to OFF indicator light or buzzer should turn
off.
C.
Move breaker handle to ON indicator light or buzzer
should remain off.
NOTE: Should the indicator not function properly during
“check” procedure, inspect for incorrect installation or
wiring .
Summary of Contents for I-T-E Sensitrip MD Series
Page 2: ......
Page 6: ...4 I T E Sensitrip Digital Circuit Breaker MD and ND Frame Outline Drawings 1 3 Pole ...
Page 8: ...6 MD and ND Frame Trip Adjustments ...
Page 12: ...10 MD and ND Frame Time Current Curve 600 1000A With Short Time Delay Set on Fixed Time ...
Page 13: ...MD and ND Frame Time Current Curve 11 1200A With Short Time Delay Set on Fixed Time ...
Page 14: ...12 MD and ND Frame Time Current Curve 600 100A With Short Time Delay Set on I2 t ...
Page 15: ...MD and ND Frame Time Current Curve 13 1200A With Short Time Delay Set on I2 t ...
Page 16: ...14 MD and ND Frame Time Current Curve 600 100A Without Short Time Settings ...
Page 17: ...MD and ND Frame Time Current Curve 15 1200A Without Short Time Settings ...
Page 18: ...16 MD and ND Frame Time Current Curve Ground Fault Trip Data ...
Page 19: ...MD and ND Frame Time Current Curve 17 Example ...
Page 20: ...18 MD and ND Frame Let Thru Curves ...
Page 31: ...Installation Diagrams 29 ...
Page 35: ...I T E Mechanical Interlock M15404 33 Figure 7 ...
Page 41: ...Installation Diagrams 39 ...
Page 49: ...Installation Diagrams 47 ...
Page 50: ...48 I T E Panelboard Connecting Straps 1 ...
Page 53: ...Installation Diagrams 51 ...