S- Registry
Pocket Modem 56k
58
Dezember 05
S13*
Number of dialing attempts to send the message
Bit Meaning
Bit 0-3
Number of dialing attempts
Range of values: 1...12
Default value: 3
S13 determines the number of attempts to send the
message.
Note:
The limitation to a maximum of 12
attempts is necessary for approval
purposes (black listing).
Bit 4-7
Reserved
S14*
General settings
Bit Meaning
Bit 0
Reserved
Bit 1
Echo on inputs
Command echo
0: Echo off
1:
Echo
on
Bit 2
Reserved
Bit 3
Result format
Result codes:
0: Message numbers (
ATV0
)
1: Message texts (
ATV1
)
Bit 4
Reserved
Bit 5
Tone/pulse dialing
Tone/pulse
0: Tone dialing (
ATT
)
1: Pulse dialing (
ATP
)
Bit 6
Reserved
Bit 7
Originate/answer
Originate/answer 0:
Answer
mode
1: Originate mode
S15*
DTC Time Settings
The idle connection control is a function integrated in the firmware which
monitors the data transmission in online mode. This function prevents the
modem to stay online for an unlimited amount of time, although no data is being
transmitted anymore.
In the registry S15, any time period between 1 and 255 seconds may be entered. If
S15 is set to 0, the idle connection control is switched off.
The timer will run immediately after the modem goes off-hook. As soon as the
timer has run out, a modem reset is performed (which will forcibly lead to the
hanging up of the modem).
S17*
Initial character for remote configuration
In S17, the ASCII code of a character which is used to start the remote
configuration, is defined. Values >127 switch the remote configuration off
completely. The default setting in S17 is “42”, which equals the ASCII character
“*”. This means that the remote configuration is started with the Escape character
sequence
<Pause> **** <Pause>
.
Note: The number of characters in the Escape sequence is fixed to “4” characters.