Installation

Installation

Preparing for installation

Caution!

Ensure that there are no electrical wires, gas pipes or 

water pipes in the area where holes are to be drilled.

If the extractor hood is to be operated in exhaust-air 

mode, a flue duct must be fitted. 
If the extractor hood is to be operated in air-recirculation 

mode, an optional accessory must be fitted. To do this, 

refer to the installation instructions provided. The flue 

duct does not need to be fitted for air-recirculation 

mode.

1.

Determine where the extractor hood should be 

positioned and lightly mark where the lower edge of 

the appliance should be on the wall. Determine 

where the middle should be based on the hob.

Note: 

We recommend fitting the extractor hood such 

that the lower edge of the glass screen is in line with 

the lower edges of the adjacent wall-hung cabinets. 

Make sure that the specified safety clearances from 

the hob are complied with.

2.

Place the template against the line drawn on the wall 

and fasten it in place. Mark where the screws should 

be inserted.

To fit the flue duct, the template must be cut along 

the marked cut line.

3.

Drill 8 mm diameter holes to a depth of 80 mm for 

fastening the appliance, remove the template and 

press in the wall plugs flush with the wall. 

$

%

]

]

[

•PP

[

•PP

[

•PP

[

•PP

\

\

Summary of Contents for iQ300 LC67KHM60B

Page 1: ...Register your product online siemens home bsh group com welcome en QVWUXFWLRQV IRU LQVWDOODWLRQ DQG XVH Extractor hood ...

Page 2: ...iance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be used by children over...

Page 3: ...ndows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the g...

Page 4: ...t the after sales service Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaner...

Page 5: ...modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed throug...

Page 6: ...y of the fan Touch the symbol 2Cleaning and maintenance Cleaningandmaintenance Warning Risk of burns The appliance becomes hot during operation Allow the appliance to cool down before cleaning Warning Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in th...

Page 7: ... water Clean the filters with a brush and then rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled m...

Page 8: ...les replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualified technician electrician only Warning Risk of injury The light emitted ...

Page 9: ...in the accessory E no FD no After sales serviceO GB 0344 892 8999 Calls charged at local or mobile rate IE 01450 2655 0 03 per minute at peak Off peak 0 0088 per minute Z Nr FD E Nr Type Accessories Order number Starter set for air recirculation mode flat hood with chimney Easy change filter for starter set LZ10AFU00 LZ10AFA00 Starter set for air recirculation mode flat hood without chimney Easy c...

Page 10: ...erated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For additional optional accessories refer to the installation instructions provided The surfaces of the appliance are sensitive Avoid damaging them during installation PLQ PP PLQ PP PD PP PLQ PP PLQ PP P...

Page 11: ...on location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Warning Risk of fire Fatty deposits in the grease filter may catch fire The specifi...

Page 12: ...al vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire...

Page 13: ...l KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks The max...

Page 14: ...hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood such that the lower edge of the glass screen is in line with the lower edges of the adjacent wall hung cabinets Make sure that the specified safety clearances from the hob are complied with 2 Place ...

Page 15: ...hout a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP ...

Page 16: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance Warning Risk of electric shock Components inside the appliance may have sharp edges These may d...

Reviews: